background image

    

TLV 10

MICROPROCESSOR-BASED

DIGITAL ELECTRONIC

THERMOMETER

OPERATING INSTRUCTIONS

Vr. 01 (ENG) - 11/05 - cod.:  ISTR 06939

TECNOLOGIC S.p.A.

VIA INDIPENDENZA 56

27029 VIGEVANO (PV) ITALY

TEL.:  +39 0381 69871

FAX: +39 0381 698730

internet : http:\\www.tecnologic.it

e-mail: [email protected]

FOREWORD

This manual contains the information
necessary for the product to be installed
correctly and also instructions for its
maintenance and use; we therefore recommend
that the utmost attention is paid to the following

instructions and to save it.
This document is the exclusive property of TECNOLOGIC
S.p.A. which forbids any reproduction and divulgation , even
in part, of the document, unless expressly authorized. 
TECNOLOGIC S.p.A. reserves the right to make any formal or
functional changes at any moment and without  any notice.
Whenever a failure or a malfunction of the device may cause
dangerous situations for persons, thing or animals, please
remember that the plant has to be equipped with additional
devices which will guarantee safety.
Tecnologic S.p.A. and its legal representatives do not assume
any responsibility for any damage to people, things or animals
deriving from violation, wrong or improper use or in any case
not in compliance with the instrument’s features.

INDICE

INSTRUMENT ORDERING CODE

7.5

FUNCTIONAL DATA

7.4

MECHANICAL DIMENSIONS, PANEL CUT-OUT AND
MOUNTING

7.3

MECHANICAL DATA

7.2

ELECTRICAL DATA

7.1

TECHNICAL DATA

7

GUARANTEE AND REPAIRS

6.3

CLEANING

6.2

SIGNALLING

6.1

PROBLEMS , MAINTENANCE AND GUARANTEE

6

PROGRAMMABLE PARAMETERS TABLE

5

PARAMETERS CONFIGURATION BY KEY01

4.2

MEASURING AND VISUALIZATION

4.1

FUNCTIONS

4

ELECTRICAL WIRING DIAGRAM

3.4

ELECTRICAL CONNECTIONS

3.3

MECHANICAL MOUNTING

3.2

PERMITTED USE

3.1

INFORMATION ON INSTALLATION AND USE 

3

PARAMETERS PROGRAMMING LEVEL

2.3

PARAMETER PROTECTION USING THE PASSWORD

2.2

PARAMETERS PROGRAMMING

2.1

PROGRAMMING

2

FRONT PANEL DESCRIPTION

1.2

GENERAL DESCRIPTION

1.1

INSTRUMENT DESCRIPTION

1

1 - INSTRUMENT DESCRIPTION

1.1 - GENERAL DESCRIPTION

TLV 10 is a digital microprocessor based thermometer. The

instrument has one input for PTC or NTC temperature probes that
can be configured. The instrument is equipped with 4 programme

keys and a 4-digit display. Other important characteristics of the
instrument are: programme parameters protection using

personalised password, configuration of parameters via the KEY 01
device and the possibility of power supply in the range 100 ... 240
VAC.

1.2 - FRONT PANEL DESCRIPTION

TLV 10

1

5

2

3

4

1 - Key P

 : Used for programming the function parameters

2 - Key DOWN

 : Used for decreasing the values to be set and for

selecting the parameters.

3 - Key UP

 : Used for increasing the value to be set and  for

selecting the parameters.

4 - Key U :

 In the “hidden” parameter programming mode it’s used

to modify the visibility of the parameters (see par. 2.3).

5 - Led SET 

: Indicates the input in programming mode and the

programming level of the parameters.

2 -  PROGRAMMING

2.1 - PARAMETERS PROGRAMMING

To access the instrument’s function parameters, press the key 

P

and keep it pressed for about 5 seconds, after which the SET led

will light up, the display will visualised the code that identifies the
first parameter. 

Using the UP and DOWN keys, the desired parameter can be
selected and pressing the P key, the display will alternately show

the parameter code and its setting that can be changed with the UP
and DOWN  keys.

TECNOLOGIC - TLV 10

 

- OPERATING INSTRUCTIONS - Vr.01 - 11/05 - ISTR 06939  - PAG. 1

Summary of Contents for TLV 10

Page 1: ...LECTRICAL WIRING DIAGRAM 3 4 ELECTRICAL CONNECTIONS 3 3 MECHANICAL MOUNTING 3 2 PERMITTED USE 3 1 INFORMATION ON INSTALLATION AND USE 3 PARAMETERS PROGRAMMING LEVEL 2 3 PARAMETER PROTECTION USING THE PASSWORD 2 2 PARAMETERS PROGRAMMING 2 1 PROGRAMMING 2 FRONT PANEL DESCRIPTION 1 2 GENERAL DESCRIPTION 1 1 INSTRUMENT DESCRIPTION 1 1 INSTRUMENT DESCRIPTION 1 1 GENERAL DESCRIPTION TLV 10 is a digital ...

Page 2: ...the provided special bracket We recommend that the gasket is mounted in order to obtain the front protection degree as declared Avoid placing the instrument in environments with very high humidity levels or dirt that may create condensation or introduction of conductive substances into the instrument Ensure adequate ventilation to the instrument and avoid installation in containers that house devi...

Page 3: ...repairs or to the replacement of the instrument The eventual opening of the housing the violation of the instrument or the improper use and installation of the product will bring about the immediate withdrawal of the warranty s effects In the event of a faulty instrument either within the period of warranty or further to its expiry please contact our sales department to obtain authorisation for se...

Page 4: ...lay resolution 1 or 0 1 Overall accuracy 0 5 fs 1 digit Sampling rate 130 ms Display 4 Digit Red h 12 mm Compliance ECC directive EMC 89 336 EN 61326 ECC directive LV 73 23 and 93 68 EN 61010 1 7 5 INSTRUMENT ORDERING CODE TLV 10 a bb c a POWER SUPPLY H 100 240 VAC L 24 VAC VDC F 12 VAC VDC bb SPECIAL CODES c SPECIAL VERSIONS TECNOLOGIC TLV 10 OPERATING INSTRUCTIONS Vr 01 11 05 ISTR 06939 PAG 4 ...