Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification.

 

All Dimension are in mm

……. 

Copyright on all products and Specifications © 

 

3

 

Twin Firebox

 

 

 

SI

 

780

 

SI

 

780T

 

SI

 

900

 

SI

 

1100

 

Firebox Width

 

A

 

780 

780 

900 

1100 

Firebox Height

 

B

 

600 

680 

750 

800 

Firebox Depth

 

C

 

700 

700 

850 

900 

Flange Width

 

D

 

830 

830 

950 

1150 

Flange Height

 

E

 

625 

705 

775 

825 

Adaptor Height

 

F

 

205 

205 

275 

275 

Cabinet Width

 

G

 

870 

870 

990 

1170 

Cabinet Height

 

H

 

1000 

1000 

1200 

1220 

Cabinet Depth

 

I

 

680 

680 

830 

880 

Centre of Flue

 

J

 

350 

350 

425 

450 

Flue

 

K

 

300 

300 

325 

350 

Flue Liner

 

L

 

400 

400 

425 

450 

Fascia Width

 

M

 

1040 

1040 

1160 

1360 

Fascia Height

 

N

 

840 

925 

995 

1045 

Heat Output

 

kW

 

  

 

  

  

Peak*

 

 

 

24 

26

 

32 

35 

Range*

 

 

 

15-17 

17-19

 

18-21 

19-22 

*Estimated unless stated otherwise.

 

WARMINGTON FIREBOX DIMENSION

 

Minimum Flue 
Height

 

 

 

Flue Height

 

4800

 

Measured From Top 

of Adaptor

 

B + F + 4800

 

FIREBOX HEAT CELL CABINET

 

Adaptor Fitting

 

Seal adaptor to firebox using high-temp 

gasket sealant.  Bolt through holes  
provided.

 

Seismic restraint

 

Secure firebox through anchor positions 

provided.

 

Check List

 

 

 

Firebox

 

 

 

Adaptor (Fastenings)

 

 

 

Ash pan

 

 

 

Bricks

 

 

 

Louvers

 

 

 

Badge

 

 

 

Damper Handle

 

 

 

Packed By

 

 

 

Note:

 

DO NOT FRAME OUT TO 
THESE DIMENSIONS  
CHECK HEAT CELL ALCOVE 
ON PAGE 5 & 6.

 

Showing sides with and without door fitted

 

Seismic 

 

Restraint

 

Located under 

bricks

 

Summary of Contents for SI 1100 Twin

Page 1: ...mington Fire Installation The Warmington unit is to be Installed by a Certified Warmington Installer or an Approved NZHHA Installation Technician See www homeheat co nz members for a Certified NZHHA S...

Page 2: ...tem Care needs to be taken to ensure that the flue termination is in the correct position to maximise performance The Prevailing Wind Care needs to be taken to ensure that the flue termination is in t...

Page 3: ...350 350 425 450 Flue K 300 300 325 350 Flue Liner L 400 400 425 450 Fascia Width M 1040 1040 1160 1360 Fascia Height N 840 925 995 1045 Heat Output kW Peak 24 26 32 35 Range 15 17 17 19 18 21 19 22 E...

Page 4: ...hielding around the fire system This is a general installation guide only Contact a NZHHA Installer for Installation Advice or go to www homeheat co nz then select Members select your Region Installer...

Page 5: ...000 1100 1350 Heat Cell Clearance Depth P 680 680 830 880 Heat Cell Clearance Height Q 1700 1700 2400 2400 Hearth Width R 1200 1200 1350 1550 Hearth Projection S 600 600 600 600 Window Height V 825 90...

Page 6: ...1550 Hearth Projection S 600 600 600 600 Plinth Width T 1000 1000 1100 1350 Plinth Depth U 680 680 830 880 Centre of Flue J 350 350 425 450 Chimney Chase Clearance X 500 500 525 550 TIMBER PLAN FRONT...

Page 7: ...Width OO 1000 1000 1210 1210 Heat Cell Clearance Depth blockwork PP 680 680 830 880 Heat Cell Clearance Height QQ 1700 1700 2400 2400 Hearth Width RR 1200 1200 1350 1550 Hearth Projection SS 600 600...

Page 8: ...ix down Assemble adaptor and flue system according to AS NZS 2918 2001 2 Fix front panel on by insuring the location tag is posi tioned at the top of the side panels Clamp secure and rivet front panel...

Page 9: ...C Method Assemble together fascia side panels and top panel us ing fastenings pro vided Slide fascia down the front flange into position no less than 15mm overlap on each side Note 4 Fixing Fascia to...

Page 10: ...with ASNZS 2918 2001 4 9 1 1 NOTE The last length of flue pipe needs to extend past the liner so that when the top spider and the Flashing cone are fitted that the flashing cone and the flue pipe are...

Page 11: ...en flashing Butynol Dectite an Additional Flue pipe Baffle is required All external air vents ceiling penetrations must be bird proofed with permanently fixed screens All flashing to comply with E2 Te...

Page 12: ...and Specifications 12 SETTING ADD COWL AND FLASHING CONE HEIGHT CHIMNEY CHASE FLASHING AND AIR VENTILATION OPTIONS VENTING THROUGH CHIMNEY CHASE VENTING THROUGH FLASHING No Insulation under flashing...

Page 13: ...in mm Copyright on all products and Specifications 13 FLUE HEIGHT MINIMUM DETAILS FRAME OUT AND TRIM OUT DETAILS FOR CHIMNEY CHASE Option X Singled Lined Flue System Option Y Double Lined Flue System...

Page 14: ...mension are in mm Copyright on all products and Specifications 14 COMBUSTIBLE MANTLE CLEARANCES HEARTH CLEARANCES Note For Combustible Floors Minimum Hearth of 380mm A must be maintained Mantle Cleara...

Page 15: ...S WARNING ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN WRITING BY THE TESTING AUTHORITY IS CONSIDERED AS BREACHING AS NZS 4013 WARNING DO NOT USE FLAMMABLE LIQUIDS OR AEROSOLS TO ST...

Reviews: