HEARTH & PLINTH CONSTRUCTION DETAILS
*Note: If Solid Plastering the Heat Cell Structure, it is recommended to use a Fibreglass Mesh with a Latex Based Plaster
to minimise the chance of the Solid Plaster cracking. (See your Solid Plasterer for correct materials and applications).
Visit the Warmington Web Site for
“
Hebel
”
instruction (PDF Download).. www.warmington.co.nz
SEISMIC RESTRAINTS
GAS SPECIFICATIONS Tested to current gas standards
NOTE : All Test Pressures are tested by a Independent Test Lab
Seismic Restraint
Secure Firebox through
anchor points provided
Hearth & Plinth
This is a raised & cantilevered hearth.
See spec for detail.
* Inlet Pressure not to exceed 4.0KPa
MODEL
SG
-
EG 700
SG
-
EG 780
SG
-
EG 900
SG
-
EG 1100
SG
-
EG 1250
LPG
Nominal Pressure kPa
2.75 kPa
2.75 kPa
2.75 kPa
2.75 kPa
2.75 kPa
Nominal Injector Size mm
2 X 1.1mm
2 X 1.2mm
2 X 1.3mm
2 X 1.4mm
4 X 1.1mm
Burner Pressure High kPa
2.5
2.5
2.5
2.5
2.5
Burner Pressure Low kPa
0.75
0.75
0.75
0.75
0.75
MJ/h
29
38
42
50
60
Flame Effect Output Only
Effect
Effect
Effect
Effect
Effect
Supply Pipe Size dia—min
3/8”
3/8”
1/2”
1/2”
1/2”
Natural Gas
Nominal Pressure kPa
1.5 kPa
1.5 kPa
1.5 kPa
1.5 kPa
1.5 kPa
Nominal Injector Size mm
2 X 1.8mm
2 X 2mm
2 X 2.2mm
2 X 2.4mm
4 X 1.8mm
Burner Pressure High kPa
1
1
1
1
0.85
Burner Pressure Low kPa
0.3
0.3
0.3
0.3
0.2
MJ/h
35
41
48
60
63
Flame Effect Output Only
Effect
Effect
Effect
Effect
Effect
Supply Pipe Size dia—min
3/8”
1/2”
1/2”
1/2”
1/2”
Lab. Test No
GL 923
GL 900
GL 834
GL 876
GL 973
Lab. Test Dates
20/04/2010
26/02/10
26/06/09
24/12/09
30/04/11
ESS Declaration No:
1149420106
1149520106
1149720106
1149820106
1149720106
Note: Hearth and Plinth construction
Plinth to be offset above hearth by the hearth finish-
ing
’
s ( e.g. Tiles / Granite / Solid Plaster / etc.)
Raised hearth
’
s & plinth
’
s with cantilevered hearth
’
s
must be adequately supported to take the weight in
accordance with the NZ Building Code.
Hearth & Plinth material must
be built with non combustible
material eg. 9.5mm Promina,
Superlux, Etapan.