background image

29 March 2021

 

Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification.

 

All Dimension are in mm

………….

Copyright © 

 

12

 

SG / EG Range: Gas Convection Fireplaces

 

  

 

FLUED  GAS  APPLIANCES

 All Gas Fires requiring Warmington Flue Systems shall be Installed to the requirements of the current standards and 

shall be appropriately designed and constructed to permit safe and effective use. This Appliance must be flued to the outside atmosphere.  All Warm-

ington Fires must be Installed with a 

minimum of 3.6m 

of Approved 

Warmington Gas Flue and Liners

.

 

GAS  TYPE

 All Gas fires shall operate safely on the Gas Type specified on the Appliance and shall comply with the requirements of The Gas Act 

1992. 

 

APPLIANCE  SAFETY

 Any Gas Fire Appliance shall comply with the safety requirements of the current standards listed under 

Related    documents

’ 

in this specification.

 

ELECTRICAL REQUIREMENTS

 All Gas Fire Appliances Installed with Mains Supplied Electrical components for associated use with these Applianc-

es, must comply with The Electricity Regulations 1993. 

 

ELECTRONIC  CONTROL  SYSTEMS

 Any Gas Fire Appliance Installed with Manual or Programmable Electronic Control System shall be tested and/

or approved by a Recognised Person or Authority. 

 

SEISMIC  RESTRAINTS

 All Fires used for Domestic and Commercial Purposes shall be firmly secured (unless defined as portable or      mobile) to 

prevent dislodgement from their point of fixture or Installation during Seismic Activity. Such Restraint must be of a reasonable expectation. 

 

GAS CONNECTION

 

 

A Gas Certificate must be obtained for the Installation and Commissioning of this appliance and flue system 

 

Check that the Gas Type Specified on the Data Plate is correct for the available supply (LPG or NG).

 

A Copper Gas supply capable of supplying the correct MJ/h, should be brought into the rear of the installation cavity through the hole provided.           

A flare nut is provided on the burner for gas connection to the appliance.

 

TO THE INSTALLER / GAS FITTER and ELECTRICIAN

 

COMMISSIONING AND TESTING  OF FIREPLACE              (To be carried out by Gasfitter)

 

Burner may be 

 

Secured

 

To the Firebox

 

(Optional)

 

Gas Supply Pipe

 

Into Fire ,

 

by Gasfitter .

 

See Spec

s for

 

Pipe Size.

 

FITMENT OF BURNER

 

Read all the instructions before commissioning. Install coals and logs and burner before commission.

 

Light appliance and check HIGH/LOW settings. Check operation of appliance and adjust to suit. 

 

Adjust control valve setting if required. After a period of running (30min Plus) check the setting of the pilot and adjust if required.                            

See Spec

s for details.

 

Extinguish appliance, remove test equipment and secure test nipple. Check for gas leaks.

 

Note: 

 

The Control Valves are factory set and should not require adjustment.

 

GAS FITTER TO CARRY OUT STANDARD TESTING FOR COMMISSION:

 

• 

Spill test taken at top of opening with smoke or smoke match.

 

• 

Leak testing appliance and joints.

 

• 

Correct operation of the burner and coal and log lay out.

 

• 

Test gas pressures high and low, drop test on supply line. 

 

• 

5 second light time across burner and other testing that may be 

 

 

required. 

 

• 

Ventilation requirements to the standards.

 

• 

Clean and or touch up paint of fire box and burner.

 

• 

Hand over to Client, test and comply to relevant 

 

 

standards.

 

 

NOTES:

 

• 

Service annually or more if required.

 

• 

Custom built to clients requirements to relevant and current standards.

 

• 

The appliance and flue system must be installed in accordance with the relevant and current standards and the appropriate building 

 

codes.

 

• 

The appliance and flue system must be tested in accordance with the relevant and current standards and the appropriate building 

 

codes.

 

Summary of Contents for SG 700

Page 1: ...allation The Warmington unit is to be installed by a certified Warmington installer or an approved NZHHA installation technician See www homeheat co nz members for a certified NZHHA SFAIT Installer in...

Page 2: ...ity to Vent the Warm Air This Warm Air helps keep the Fire and Flue System form getting to Cold If the Flue and Fire get to Cold the System may soot often and require cleaning Each Fire has different...

Page 3: ...855 855 855 1205 Cabinet Depth C 525 525 525 525 564 Fascia Width D 865 940 1065 1260 1420 Fascia Height E 680 680 680 680 677 Centre of Flue F 315 315 285 285 336 Flue G 200 200 250 250 300 Flue Oute...

Page 4: ...r Size mm 2 X 1 1mm 2 X 1 2mm 2 X 1 3mm 2 X 1 4mm 4 X 1 1mm Burner Pressure High kPa 2 5 2 5 2 5 2 5 2 5 Burner Pressure Low kPa 0 75 0 75 0 75 0 75 0 75 MJ h 29 38 42 50 60 Flame Effect Output Only E...

Page 5: ...1700 1850 Hearth Projection Q 300 300 300 300 300 To Wall Side R 100 100 100 100 100 To Wall Behind S 100 100 100 100 100 To Flue Centre T 340 340 340 340 330 Hearth Depth Corner Y 1550 1590 1650 1750...

Page 6: ...e place Caitec weir vent system as close to fireplace as possible CAITEC TECHONOLGY ROOM AIR REPLACEMENT Caitec draws air from an external air source to ensure that combustion air that the open fire u...

Page 7: ...t the Top Spider into position ensure that the legs of the spider are fitted inside the liner and that the spider is positioned hard down onto the liner and tighten with the screw and nut 3 Place the...

Page 8: ...041 20th July 2004 FLUE PENETRATION vented through alcove double lined flue system FLUE PENETRATION Vented through Top Flashing Note External requirements Refer to relevant standards Install flue syst...

Page 9: ...CHASE FLASHING AND AIR VENTILATION OPTIONS VENTING THROUGH CHIMNEY CHASE No Insulation under flashing VENTING THROUGH FLASHING Insulation under flashing Note Flashing spigot height is determined by t...

Page 10: ...ange product specifications without prior notification All Dimension are in mm Copyright 10 FLUE HEIGHT MINIMUM DETAILS FRAME OUT AND TRIM OUT DETAILS FOR CHIMNEY CHASE The flue exit is to comply to r...

Page 11: ...the right to change product specifications without prior notification All Dimension are in mm Copyright 11 Note For Combustible Floors Minimum Hearth of 300mm A must be maintained at any given height...

Page 12: ...ified on the Data Plate is correct for the available supply LPG or NG A Copper Gas supply capable of supplying the correct MJ h should be brought into the rear of the installation cavity through the h...

Page 13: ...Logs and twigs may be scattered to achieve best visual effect Fit Burner grate by sliding R L side metal pins on grate into holes located on burner side plates as shown below 2 Top Row Slide R LH Grat...

Page 14: ...o light all the way across Once the flame is established adjust to the desired setting and close the cover To shut down Open the cover by pulling it outwards Turn the control ignition switch to PILOT...

Page 15: ...sired pressure see spec s Extinguish Appliance remove test equipment and secure test nipple Check valve burner for correct operation check fire for gas leaks Note When the base screw is removed gas wi...

Page 16: ...to observe the following precautions associated with any heating appliance or open fire Do not cover or restrict the fireplace upper or lower vents in any way as this may result in a build up of hazar...

Page 17: ...Copyright 17 Option 2 Three speed fan as additional option on SG units or EG units without remote controlled electronics eg units with on off hi low switches on the wall Option 1 Single speed fan as...

Page 18: ...to the hi kPa value in the table for maximum output test point inlet Modulator Harness Connections 1 2 BSPT gas outlet SIT 840 Control Valve test point outlet 1 2 BSPT gas inlet adjustment screw After...

Page 19: ...21 Due to continued product improvement Warmington Ind LTD reserves the right to change product specifications without prior notification All Dimension are in mm Copyright 19 ON OFF SWITCH SIT 840 WIR...

Page 20: ...crew B to Increase the Pressure and Screw it Out to Decrease the Pressure Carefully replace the Modulator Plas tic Cap Set the pressure to the hi kPa value in the table for maximum output The burner w...

Page 21: ...1 Due to continued product improvement Warmington Ind LTD reserves the right to change product specifications without prior notification All Dimension are in mm Copyright 21 HIGH LOW SWITCH SIT 845 WI...

Page 22: ...Press and hold the or button for 2 seconds or longer to in crease or decrease the day of the week by 1 day every 0 5 seconds Press OK to complete setting The time and day of the week is now set SETTI...

Page 23: ...WE TH FR MO TU WE TH FR SA SU SU SA MO TU WE TH FR SA SU To accept the selected day s of the week press OK First period s start time The display will indicate P1 on the top The Hour and AM PM settings...

Page 24: ...Google Play Store https play google com store apps details id com millec intelligythermostatmkii For instructions on how to push the appliance to your Wi Fi please go to the Warmington website and fi...

Page 25: ...irst and once this is on it will ignite the main burner Pressing and releasing the power button again will switch off the appliance When the appliance is turned on the gas fire will be set to medium f...

Page 26: ...to pressure is to be carried out by a Certified Gasfitter If adjustments are necessary remove the cap The Pressure Adjustment screw and nut are on the front side of the Gas Control Valve shown in dia...

Page 27: ...tisfied that the appliance is working correctly fit the front panel assembly back to the gas burner NOTE Ensure you peel the Protective Plastic Coating from any stainless steel components if fitted Al...

Page 28: ...Due to continued product improvement Warmington Ind LTD reserves the right to change product specifications without prior notification All Dimension are in mm Copyright 28 FULLY MODULATING SIT 845 WI...

Page 29: ...te building codes This appliance must be serviced annually and any service operation must be carried out by a qualified service person WARNINGS WARNING ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT B...

Reviews: