background image

CSCA-799

Custom Pan Burner 

12028 E. Philadelphia St. Whittier , CA 90601  U.S.A.

(562) 696-8718        FAX (562) 698-3510

E-Mail: [email protected]  Web http://www.riwinc.com

GENERAL INSTALLATION INSTRUCTIONS

ASSEMBLY, INSTALLATION, AND OPERATION INSTRUCTIONS FOR RASMUSSEN

VENTED CUSTOM PAN BURNER MODELS:

CS; CS-W (Wide) for use with Natural Gas

CA; CA-W (Wide) for use with Propane (LP) Gas

IMPORTANT

READ THESE INSTRUCTIONS CAREFULLY BEFORE
STARTING INSTALLATION OF LOG SET.

WARNING:

 

Improper 

installation,

alteration,  service  or  maintenance  can  cause
injury  or  property 

damage. 

Read 

these

instructions thoroughly before installation.  For
assistance  or  additional  information,  consult
your gas log dealer, qualified installer, service
agency or gas supplier.

FOR YOUR SAFETY

Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.

FOR YOUR SAFETY

WHAT TO DO IF YOU SMELL GAS

   

Do not try to light any appliance.

Do not touch any electrical switch; do not use
any phone in your building.

Immediately  call  your  gas  supplier  from  a
neighbors  phone.  Follow  the  gas  suppliers
instructions.

If you cannot reach your gas supplier, call the
fire department.

IMPORTANT INFORMATION

THIS GAS LOG SET MUST BE INSTALLED IN A FULLY VENTED

SOLID-FUEL BURNING FIREPLACE WITH A WORKING FLUE

CONSTRUCTED OF NON COMBUSTIBLE MATERIAL.

The minimum permanent free opening of the fireplace chimney or chimney damper must be at least 39 square inches
based on a minimum chimney height of at least 8 feet. The area of the flue must not be less than 1/10 the area of the
fireplace opening. The flue must exhaust all products of combustion.

The chimney damper must be fixed in a manner to maintain permanent free opening as outlined above at all times. To
accomplish this, install the damper clamp (provided) on the edge of the damper blade to prevent
its closing, drill a hole or holes in the damper, or remove damper completely.

The minimum size of the fireplace in which the log set is to be installed must be as follows:

MINIMUM FIREPLACE SIZE IN INCHES

LOG SET SIZE

HEIGHT

D E P T H

WIDTH

CHIMNEY

18 INCH
24 INCH
30 INCH

.

16
16
16

.

13
13
13

.

24
32
36

.

7 INCH DIAMETER
7 INCH DIAMETER
8 INCH DIAMETER

.

Glass doors must be wide open when burner is lighted

to allow air for safe combustion and venting.

THIS BURNER IS FOR USE IN FULLY FUNCTIONING WOOD BURNING

FIREPLACE WITH THE DAMPER WIDE OPEN.

THE FLUE MUST VENT ALL PRODUCTS OF COMBUSTION.

.

f i r e - p a r t s . c o m

Summary of Contents for CS

Page 1: ...ot reach your gas supplier call the fire department IMPORTANT INFORMATION THIS GAS LOG SET MUST BE INSTALLED IN A FULLY VENTED SOLID FUEL BURNING FIREPLACE WITH A WORKING FLUE CONSTRUCTED OF NON COMBUSTIBLE MATERIAL The minimum permanent free opening of the fireplace chimney or chimney damper must be at least 39 square inches based on a minimum chimney height of at least 8 feet The area of the flu...

Page 2: ...rner WARNING CARBON MONOXIDE POISONING MAY LEAD TO DEATH When used without fresh air gas log set may give off carbon monoxide an odorless colorless poisonous gas Some people pregnant women persons with heart or lung disease anemia or under the influence of alcohol and persons at high altitudes are more affected by carbon monoxide than others Early signs of carbon monoxide poisoning resemble the fl...

Page 3: ...ecurely to ensure mechanical strength and a tight gas seal Repeat for all four legs See Figure 2 NOTE In extremely low fireplaces or where andirons are being used the LEGS may be left off HOWEVER TO PREVENT GAS LEAKING BENEATH THE BURNER PAN THE NUT BOLT AND FIBER WASHER MUST BE INSTALLED TO ENSURE GAS TIGHT INTEGRITY Standard Match Lighted For use only with Natural Gas Models CS CS W WARNING A SA...

Page 4: ...o BURNER PAN AIR MIXER CA CA W or BURNER PAN REDUCING COUPLING CS CS W and using wrench placed onto VALVE at the WRENCH ATTACH POINT tighten to the position shown at Figure 7 C Attach Pilot Thermocouple 1 Align the PILOT THERMOCOUPLE ASSEMBLY on side of BURNER PAN as shown in Figure 7 Using NUT and BOLT through pre punched hole in side of burner pan attach ANGLE BRACKET ensuring that the PILOT BUR...

Page 5: ...nd to the FLARED BURNER INPUT FITTING D Wrench tighten Figure 12 NOTE If bent into too small a radius the ALUMINUM CONNECTOR TUBE C may kink or break causing air flow noise and or leaks 4 Turn gas supply to fireplace on 5 Test all connections for leaks with soapy water solution If solution bubbles turn off gas supply re tighten fitting and recheck WARNING DO NOT FLAME TEST FOR LEAKS STEP FOUR Whit...

Page 6: ...PLY VALVE completely MANUAL MATCH LIGHTING WITH ACCESSORY V17 VALVE Match Lighted V17 Valve Applies only to Natural Gas Models CS or CS W 1 Ensure that MANUAL V17 VALVE is completely closed See FIGURE 5 2 Open FIREPLACE GAS SUPPLY VALVE See FIGURE 7 3 Place lighted match on embers near inlet end of burner DO NOT HOLD MATCH IN HAND 4 Slowly open MANUAL V17 VALVE and wait for burner to light 5 Adjus...

Page 7: ...fference between hot tip and cold junction base Check that thermocouple assembly is installed on side of burner on bracket per instructions Check that only tip of thermocouple is in main burner flame Remove then replace logs to alter heat radiation pattern Ensure that glass doors are open Ensure that proper size gas log set is installed Too large of a set decreases cooling air flow ACCESSORY RPK1 ...

Page 8: ...mages of any kind whether based upon warranty contract or negligence arising in connection with the sale use or repair of the product Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you 3 The maximum liability of RASMUSSEN in connection with this limited warranty shall not in any case exceed the contr...