SG Range: Gas Convection Fireplaces

 

   

 

 

 

 

FLUED  GAS  APPLIANCES

 All Gas Fires requiring Warmington Flue Systems shall be Installed to the requirements of the current standards and 

shall be appropriately designed and constructed to permit safe and effective use. This Appliance must be flued to the outside atmosphere.  All Warm-
ington Fires must be Installed with a 

minimum of 3.6m 

of Approved 

Warmington Gas Flue and Liners

GAS  TYPE

 All Gas Fires shall operate safely on the Gas Type specified on the Appliance and shall comply with the requirements of The Gas Act 

1992.  

APPLIANCE  SAFETY

 Any gas fire appliance shall comply with the safety requirements of the current standards listed under “Related documents” in 

this specification. 

ELECTRICAL  REQUIREMENTS

 All Gas Fire Appliances Installed with Mains Supplied Electrical components for associated use with these Appli-

ances, must comply with The Electricity Regulations 1993.  

ELECTRONIC  CONTROL SYSTEMS

 Any Gas Fire Appliance Installed with Manual or Programmable Electronic Control System shall be tested and/

or approved by a Recognised Person or Authority.  

SEISMIC  RESTRAINTS

 All Fires used for Domestic and Commercial Purposes shall be firmly secured (unless defined as portable or mobile) to pre-

vent dislodgement from their point of fixture or Installation during Seismic Activity. Such Restraint must be of a reasonable expectation.  

GAS CONNECTION

  

A Gas Certificate must be obtained for the Installation and Commissioning of this Appliance and Flue System. 

Check that the Gas Type Specified on the Data Plate is correct for the available supply (LPG or NG). 

A Copper Gas supply capable of supplying the correct MJ/h , should be brought into the rear of the Installation Cavity through the hole provided. A 
Flare Nut is provided on the Burner for Gas Connection to the Appliance. 

TO THE INSTALLER / GAS FITTER and ELECTRICIAN

 

COMMISSIONING AND TESTING  OF FIREPLACE              (To be carried out by Gasfitter)

 

Burner may be  

Secured 

To the Firebox 

(Optional) 

Read all the instructions before commissioning. Install coals and logs and burner before commission. 

Light appliance and check HIGH/LOW settings. Check operation of appliance and adjust to suit.  

Adjust control valve setting if required. After a period of running (30min Plus) check the setting of the pilot and adjust if required. See Spec’s for details. 

Extinguish appliance, remove test equipment and secure test nipple. Check for Gas Leaks. 

Note*   The Control Valves are factory set and should not require adjustment. 

GAS FITTER TO CARRY OUT STANDARD TESTING FOR COMMISSION: 

Spill test taken at top of opening with smoke or smoke match . 

 leak testing appliance and joints . 

correct operation of the burner and coal and log lay out .  

test gas pressures high and low, drop test on supply line .  

5 second light time across burner, Other testing that may be required .  

Ventilation requirements to the standards . 

Hand over to Client, tests and comply to relevant standards. 

FITMENT OF BURNER

 

Gas Supply Pipe 

Into Fire, 

by Gasfitter. 

See Specs for 

Pipe Size. 

NOTES: 

 

Service annually or more if required. 

 

Custom built to clients requirements to relevant and current standards. 

 

The appliance and flue system must be installed in accordance with the relevant and current standards and the appropriate building codes. 

 

The appliance and flue system must be tested in accordance with the relevant and current standards and the appropriate building codes. 

Summary of Contents for SG 700

Page 1: ...ion The Warmington unit is to be installed by a certified Warmington installer or an approved NZHHA installation technician See www homeheat co nz members for a certified NZHHA SFAIT Installer in your...

Page 2: ...on the pressure difference from inside the building to the outside A lower pressure in the building may induce a draft down the flue system and back into the building causing the fire to smoke or spil...

Page 3: ...rner Width A 674 754 874 1074 Burner Height B 205 205 205 205 Burner Depth C 272 272 272 272 Flue Diameter Min J 200 200 250 250 Flue CSA mm K 31 416 31 416 49 087 49 087 WARMINGTON BURNERS NOTE IMPOR...

Page 4: ...ctor Size mm 2 X 1 1mm 2 X 1 2mm 2 X 1 3mm 2 X 1 4mm Burner Pressure High kPa 2 5 2 5 2 5 2 5 Burner Pressure Low kPa 0 75 0 75 0 75 0 75 MJ h 29 38 42 50 Flame Effect Output Only Effect Effect Effect...

Page 5: ...hat the Gas Type Specified on the Data Plate is correct for the available supply LPG or NG A Copper Gas supply capable of supplying the correct MJ h should be brought into the rear of the Installation...

Page 6: ...roughest Face Outward Ensure Coal positioning does not directly block the 3 Flame Pilot The placement of the Coals Logs may vary to make an even Flame Pattern Logs and Twigs may be scattered to achie...

Page 7: ...ng the Switch in a Depressed State repeat steps 2 3 if necessary Once the Pilot Flame is lit hold this position for 3 5 seconds release from the Depressed State before setting the Flame Control to Ful...

Page 8: ...rol Valves are Factory Set but may require adjustment onsite Turn Appliance Off Remove Front Plastic Cover on Igniter Pull Cover to Slide off Unscrew Test Nipple on the Burner Manifold fit the Test Ga...

Page 9: ...es on the principle of dual radiant and convected heat Therefore it is important to observe the following precautions associated with any heating appliance or open fire Do not cover or restrict the fi...

Page 10: ...adjust to Low Flame and check pres sure NOTE If setting the Pressure is required it is to be carried out by a Certified Gas Fitter If adjustments are necessary remove the cap The Pressure Adjustment S...

Page 11: ...serviced annually and any service operation must be carried out by a qualified service person WARNINGS WARNING ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN WRITING BY THE TESTING AU...