7.2.3. VIWA 90, 115, 125 AND 150 BOILERS AND CASCADE SYSTEM AND 3 OR 4 HIGH TEMPERATURE (RADIATOR)
SYSTEM BOILERS AND MLC 30 ELECTRICAL CONNECTION DIAGRAM
INS
TALLA
TION EQUIPMENT
S
1. Boiler 2. G
as Saf
ety Solenoid V
alv
e
3. Ball V
alv
e
4. G
as Filt
er
5. Vibr
ation İsola
tor
6. C
ondensa
te Siphon and Dr
ainage
Line
7. Check V
alv
e
8. Boiler (R
eturn) P
ump
9
. A
ut
oma
tic Air P
ur
ge V
alv
e
10
. Sediment-Dirt-
Air Separ
at
or
11. Manometr
e
12. Hy
dr
aulic Separ
at
or Sensor
13. Hy
dr
aulic Separ
at
or
14. Sediment-Dirt Separ
at
or
15. Hea
ting S
ys
tem S
team W
at
er
C
ollect
or
16. Hea
ting S
ys
tem R
eturn W
at
er
C
ollect
or
17
. Hea
ting S
ys
tem P
ump
18. Hea
ting S
ys
tem
19
. Pr
es
sur
e R
educ
er
20
. Hot W
at
er S
tor
age T
ank
21. Hot W
at
er S
tor
age T
ank P
ump
22. Hot W
at
er S
tor
age T
ank Sensor
23. Air Separ
at
or
24. Hot W
at
er S
tor
age T
ank
R
ecir
cula
tion Line
25. R
ecir
cula
tion P
ump
26. Saf
ety V
alv
e
27
. Expansion T
ank
28. Filt
er
29
. Timer
/R
oom T
hermos
ta
t
30
. Boiler Electrical P
anel
31. Outside T
emper
atur
e Sensor
34. ML
C 30 - OPTIONAL KIT
Boiler panel and Electrical Panel connection for System Pump 3 x 1.0 mm
2
Low Temperature System Pump Boiler Panel Relay Connection 3 x 1.0 mm
2
Hot Water Storage Tank - Pump Boiler Panel Relay Connection 3 x 1.0 mm
2
Recirculation Pump and Boiler Panel Relay Connection 3 x 1.0 mm
2
Outside Temperature Sensor 2 x 1.0 mm
2
Programable Room Thermostat for 1. Zone and Hot Water Storage Tank
Timer/Room Thermostat 2 x 1.0 mm
2
Timer/Room Thermostat 2 x 1.0 mm
2
Timer/Room Thermostat 2 x 1.0 mm
2
Timer/Room Thermostat 2 x 1.0 mm
2
2. Zone Timer/Room Thermostat
3. Zone Timer/Room Thermostat
4. Zone Timer/Room Thermostat
FLUE OUTLET
FLUE OUTLET
FLUE OUTLET
System Pump HT - Z1
System Pump HT - Z2
System Pump HT - Z3
System Pump HT - Z4
Pump cable 3 x 1.0 mm
2
Pump cable 3 x 1.0 mm
2
Hydraulic Separator Sensor 2 x 1.0 mm
2
GAS LINE
COLD
WATER
COLD
WATER
RECIRCULATION CIRCUIT
Recirculation Pump
Hot Water Storage Tank Pump
Hot Water
Storage Tank
UnitTemperature
Probe
2 x 1.0 mm
2
8. Boiler
/Sla
ve
2. Boiler
/Sla
ve
1. Boiler
/Mas
ter
Main Electrical Panel
ATTENTION: OPTIONAL MLC 30 USED See Appendix-2 for MLC 30 Connection
TSP-P
ARAMETER SETTING
MA
STER
SLA
VE
(Number of Cascade Boilers
)
MA
STER BOILER
ELECTRICAL SCHEMA
SLA
VE BOILER
ELECTRICAL SCHEMA
Hot W
at
er S
tor
age
Tank Sensor
Hot W
at
er S
tor
age
Tank Sensor
BRIDGE
Outside T
emper
atur
e
Sensor
ML
C 30
R
ecir
cula
tion Pump
phase output
Hy
dr
aulic
Separ
at
or