![Warmhaus VIWA 115 Technical & Service Manual Download Page 27](http://html1.mh-extra.com/html/warmhaus/viwa-115/viwa-115_technical-and-service-manual_872639027.webp)
27
warmhaus.com.tr
INFO 7:
Display of heating flow ( CH ) SET temperature ZONE 2.
11
INFO 8:
Display of ionisation current (
μ
A).
12
INFO 9:
Display of fan speed in rpm x100.
(ie. 33 x 100 = 3300 rpm)
13
INFO 10:
Display of number of hours of the burner in hour x 100
(ie. 6.8 x 100 = 6800 hours)
14
INFO 11:
Display of number of times the burner has ignited x 1000
(ie. 23 x 1000 = 23.000 times)
15
INFO 12:
Display of number of total number of errors.
(ie. 18 = 18 times)
16
INFO 13:
Display of number of INSTALLER parameters ( Par 1-49) accessed.
Counter-installer.
(ie. 15 = Parameter menu Par 1 - 49 has been 15 times activated)
17
INFO 14:
Display of number of OEM parameters ( Par 51-99) accessed.
Counter-OEM
(ie. 11 = Parameter menu Par 51 - 99 has been 11 times activated)
18
INFO 15:
Access counter parameters CASCADE OEM
(ie. 4 = 4 access)
19
INFO 17:
Not used.