2.3.5. Boiler Components 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.  USER SECTION 

3.1.  GENERAL WARNINGS FOR USER 

3.1.1. Use of Combi

If a gas odour is present, close home entrance line and gas valves of 

your combi or close the LPG tank valve or tube valve if bulk 

gas is used. Do not switch  electricity buttons and do not do 

anything those may create sparks. Call the gas company

or Authorized Service. (See 1.3 GAS LEAKAGES, Page 6)

First start should be performed by the Warmhaus Authorized Service 

for your safety and preventing void warranty scope. Our Authorized 

Service will give you required information about use of combi after 

performing initial controls of your combi and starting for the first time.

Perform below given controls prior to starting to use:

• Ensure that radiator/heating system, tap water and gas valves located 

under your combi are open,

• the radiator installation pressure is between 1 - 1,5 bar on the 

manometer located under the Combi and system air is discharged,

• Gas is available in your gas line (you can control by igniting one of 

your gas ovens),

• Combi electrical fuse is open,

• No flammable materials and products are available near to the 

Combi,

• Ensure exhaust gas flue set output is not blocked,

• If a room thermostat or control device is connected, ensure that it is 

in the ON position.

If you  shut-off the combi for a long period, perform below written 

operations:

• Discharge the radiator installation water not containing anti-freeze,

• Close combi electrical fuse, gas valve, radiator and tap water valves!,

If you will shut-off the combi for a short period, perform below written 

operations:

• Do not close combi electrical fuse, gas valve, radiator and tap water 

valves!

• Leave the Combi at Summer position and activate its Frost Protection 

function,

Shut-off the combi during maintenance and repair operations to be 

performed around exhaust gas discharge flues. After operations are 

completed, have the combi controlled by Warmhaus Authorized 

Service prior to starting the combi.

Follow below given main rules:

 

• Do not clean external frame of combi while combi is functioning and 

do not use flammable 

materials.

• Do not touch the combi with wet hands or feet; also without shoes 

and with bare feet.

• Do not unpick electricity cables.

• In case cables are damaged, shut-off the combi and fuse switches and 

do not use the combi.

• Electrical cables of combi and it’s accessories should only be replaced 

by the Authorized Service.

3.1.2. External Weather Temperature Sensor Use (Optional)

External Weather Temperature Sensor (optional) can be installed  in 

your combi by our Authorized Service (see: Installation section; 

Accessory Connection Scheme), and you can enable automatic

Figure 25 

Components of Combi 

1. Fan

2.  Hood Fume

3.  Burning Chamber

4.  Radiator (CH) Output Pipe

5.  Safety Thermostat

6.  Observation Glass

7. Boiler

8.  Heat Reflector

9.  Gas Inlet Pipe

10. 3 way motorized valve

11.  Low Water Pressure Switch

12. Domestic Hot. Water Output Sensor

13. Fan Flue Output End

14. Expansion Tank valve

15. Expansion Tank

16. Radiator (CH) Return Pipe

17.  Lower Heat Reflector

18.  Expansion Tank Connection Pipe

19. Pump

20. Exchanger  with  Plate

21. 3 Bars Safety Valve

22. Gas Valve

23. Deflector  Plate

24. Main  Exchanger

25. Burning  Chamber  Insulation

26. Ignition and Ionization Electrode

27. Diffuser Plate

28. Automatic Air  Relief Cock

29. Control  Panel

30. Filling Tap

1

2

3

5

6

7

8
9

10

11

12

13
14

15

16

17

19

20

21

22

30

27

26

7

25

24

23

29

4

18

8

28

Summary of Contents for LAWA

Page 1: ...CONVENTIONAL COMBI BOILERS INSTALLATION USER MANUAL LAWA LAWAPLUS...

Page 2: ...Lawa LawaPlus Enerwa E24 EnerwaPLUSE24...

Page 3: ...Connections 2 2 17 Optional Controls Room Thermostat External Weather Temperature Sensor and Others 2 3 HYDRAULIC INSTALLATION RULES 2 3 1 Radiator Heating Water Structure 2 3 2 Filling Emptying Radi...

Page 4: ...under any circumstances during installation use or maintenance operations and device warranty shall also be void Only the authorized Warmhaus Service is authorized to make the electrical connection of...

Page 5: ...2 Installation Notes Figure 5 Exhaust gas flue set Do not use lighter matches Close valves of devices operating with natural gas and your gas meter Immediately evacuate the place with gas odour Natur...

Page 6: ...for the combi boiler should be well secured The hanger plate given as standard with the combi should be installed according to the technique to a full or semi full brick wall according to installatio...

Page 7: ...al operations Various alloy layers may be formed during transit of LPG gas in tanks depending on mixture compositions That causes a change in heating power of mixture assigned to the device and may co...

Page 8: ...nd all wastes must be cleaned 2 2 10 Exhaust Gas Flue Pipe Set and Accessories Connection Flue accessory sets to be used in exhaust gas installation of Hermetic combis should be original Warmhaus flue...

Page 9: ...nnection bolt installed on 90 flue bend of your combi to the flue output terminal and the clamp 3 should be insatlled on the EPDM connection bolt and slightly tighten with screw Figure 12 Then fit the...

Page 10: ...Set Bend 45 b Flue Extension Pipe c Additional 90 Bend d Standard Flue Set Pipe Figure 16 II Two 90 bended sample flue installations d a b c a b c d 4 m Figure 14 Installation of reduction stamp Pipe...

Page 11: ...ment temperature Lowest Temperature 5 C In case the combi is installed in an environment with a temperature lower than 5 C and gas supply is interrupted or passed into failure due to failing to make i...

Page 12: ...poles and relying on the earth connection high voltage category 3rd class multiple poled disconnected should be envisaged on the same grid Your device is designed as enabling normal functioning betwee...

Page 13: ...ef valves of the radiator Combi safety valve relief should be connected to a discharge cone Otherwise safety valve shall be activated and manufacturer shall not be responsible due to water discharge a...

Page 14: ...ical fuse gas valve radiator and tap water valves Leave the Combi at Summer position and activate its Frost Protection function Shut off the combi during maintenance and repair operations to be perfor...

Page 15: ...navy blue coloured backlight LCD screen 2 buttons Radiator 3 and Hot Tap Water 4 and 2 pcs RESET 2 and MODE 1 pushbuttons RESET It is used for re starting the combi and eliminating the failure in cas...

Page 16: ...light turns off At that position you can adjust the temperature between 35 80 C with the Radiator CH temperature adjustment button 3 Temperature value increases when button is rotated clockwise or dec...

Page 17: ...s lower than this value 18 Failure indicator The temperature value displayed on the combi screen has a 3 C tolerance depending on environmental conditions not arising from the combi Screen of PriwaPlu...

Page 18: ...is the temperature value of water in the installation Hold the MODE button for switching on the combi when letter is available on the screen A cycle starts on the screen release the button when cycle...

Page 19: ...diate responses to external weather temperature changes via smart and comfort operation Figure 32 Therefore it maintains an efficient and economic operation by reducing the radiator water temperaturew...

Page 20: ...for LAWA PRIWA and ENERWA models Air discharge function can be activated by pressing the RESET button more than 5 seconds while CH button and DHW button are at maximum position Upon activation of thi...

Page 21: ...uilding are open Call the authorized service in case of repeated after reset 1 E 42 Failure in pushbuttons Button failure Call the authorized service 1 E 43 Room thermostat OT communication failure Di...

Page 22: ...time you must at least execute maintenance operations on a yearly basis in compliance with what is stated in the relative point at annual check and maintenance of the appliance in compliance with nat...

Page 23: ...c Hot Water Heat Output kW 7 7 Max Domestic Hot Water flow rate t 30 C min 10 9 10 9 Min Domestic Hot Water flow rate min 1 5 1 5 Maximum water pressure bar 10 10 Minimum water pressure bar 1 5 1 5 Te...

Page 24: ...0 25 37 I2H I2E I2E I2L I2ELL I 2H I3P NUMBER OF CHOOSED CONNECTING CONDITIONS Used gas G20 G20 G25 G25 G20 G25 G20 G31 Countries of destination AT BG CH CZ DK EE ES FI GB GR IE IT LT LV NO PT RO SE S...

Page 25: ...25...

Page 26: ...26...

Page 27: ...27...

Page 28: ...CONVENTIONAL COMBI BOILERS INSTALLATION USER MANUAL LAWA LAWAPLUS Instruction booklet code of Lawa LawaPlus 150 11 606 000004 Revision Date 12 2016...

Reviews: