6 APPENDIX A: TABLES FOR MINIMUM CIRCULATING VOLUME
CALCULATION.
Typical Pipe Volumes
Pipe Type
O.D. (mm)
I.D. (mm)
Volume per metre (l)
Copper (Table X)
15
13.6
0.145
22
20.2
0.320
28
26.2
0.539
35
32.6
0.835
PEX
10
7.4
0.043
12
8
0.050
16
12
0.113
Plastic (Push Fit)
15
12
0.113
22
18
0.254
28
22.8
0.408
Typical Radiator (Emitter) Volumes
Radiator Height (mm)
Volume per metre (l)
Single Panel
Double Panel
Triple Panel
300
1.89
3.70
5.40
450
2.57
5.15
-
500
-
-
8.33
600
3.25
6.60
9.80
700
3.77
7.63
11.37