Programme settings
97
Setting the temper-
ature and time
The drying phase consists of two blocks. The temperature and dura-
tion (holding time) must be set for each block.
The first block (temperature 1 and drying time 1) is not assigned in all
programmes, but if necessary can be set up by the W&H Customer
Service Department.
Setting temperat-
ure 1
...
Temperature 1
Temperature 1
75
(50 - 115
°C
°C)
The temperature is set in 5 ° increments. The possible range is shown
in the bottom line of the display.
Use the arrow buttons
(higher) and
(lower) to set the temperat-
ure.
Press
OK
to save the setting.
Setting drying time
1
...
Drying time 1
Drying time 1
30
(0 - 120
Min
Min)
The holding time is set in 1 minute increments. The possible range is
shown in the bottom line of the display.
Use the arrow buttons
(higher) and
(lower) to set the holding
time.
Press
OK
to save the setting.
Setting temperat-
ure 2
...
Temperature 2
Temperature 2
75
(50 - 115
°C
°C)
The temperature is set in 5 ° increments. The possible range is shown
in the bottom line of the display.
Use the arrow buttons
(higher) and
(lower) to set the temperat-
ure.
Press
OK
to save the setting.