34
3.3 Datas
Type
108 49
Nominal performance
6 kW
Heating capacity contin../discontin.m
3
-under favourable
-less favourable
-not favourable heating circumstances
according to 18893/TAB2 DIN standard
165 / 116
95 / 69
65 / 47
Flue gas values: fuel:
Flue gas stream:
Flue gas temperature:
Min. blast pressure at performance:
CO (relating to 13% O²)
dust (relating to 13% O²)
efficiency
wood / brown coal
7,0 / 6,2 g/s
264 / 276 ˚C
210/229 ˚C
12 Pa
0,09 / 0,06 %
1138 / 753 mg/m³
≤
40 mg/m³
≥
80,4 % / 80,2 %
All information provided by the exhaust gas values are based on the EN 13240 under stationary
laboratory conditions reserves the right to make changes which relate to technical advances and /
or to an improvement in quality. We accept no liability for printing errors and changes which occur
after printing
Haus – und Küchentechnik GmbH
Adalperostr. 86
D – 85737 Ismaning
T49 (0)89 32084-0
T49 (0)89 32084-294
www.wamsler.eu