Filling quantities 6 kW
- Split billet: max. length: 25 cm, max. 2 billets per filling, appr. 1,4 kg
- Lignite briquette: max. 1,7 kg
Filling quantities continuos combustion:
- Lignite briquette: max. 5,8 kg
IT IS NOT ALLOWED to burn waste, fine chipping, bark, wood handled with preven-
tive chemicals, furthermore paper and cardboard. For kindling please use wood scrap-
ings or grill starter but never use liquid auxiliaries!
The first kindling
•
At the first fire set-up could be a little smoke, but is not dangerous, normal!
In this time, please ventilate the room carefully!
Warning! Upon the first kindling, smoke and unpleasant smell may be gener-
ated. Always ensure the proper ventilation of the room (by opening windows
and doors), and heat the fireplace at maximum rated heating performance. If
with the first heating the maximum temperature is not reached, the above-
mentioned effects may as well arise later on.
•
Before installation pull out the delivery securer off the refractory brick through the
furnace chamber (picture 6).
Open the door by raising the handle (picture 2). If the equipment is hot, you can use
insulated gloves. Adjust the primary air regulator and the fuel switch (picture 3) ac-
cording to the Table 2. Put coal lighter or wood wool onto the fire grate, followed by
wood chips. First insert small pieces of wood, and then larger ones, light them and
close the door again. When the wood burns quickly, and leaves sufficient glowing
embers, put additional fuel on the fire. Thereafter, adjust the primary air regulator and
the fuel switch according to the Table 2 („Adjustment of the burning air”). The first
kindling should be performed “finely” with little fuel only, so that the parts of the fire-
place are adapted to heat. During the first kindling, the generation of smell is normal
and absolutely undangerous.
1.3 Putting out of operation
•
Let the glowing ember burn to ashes and the fire-place get cold.
•
Empty the furnace chamber and the ash bin.
•
Close the doors, and shut off the primary air regulator (position I) and the fuel
switch (position K).
1.4 Heating instructions
The fireplace should be operated only with closed furnace chamber door. Fireplaces
belonging to type 1 have self-locking furnace chamber doors. These doors may be
opened only for kindling, loading or when cleaning the furnace chamber (otherwise
draught problems may occur with other equipment connected to the same chimney).
Warning!
When opening the furnace chamber door, any incorrect handling or insufficient
draught may induce smoke. Always ensure that the furnace chamber door may
be opened only slowly, first just to a small extent, and then fully after a few sec-
Summary of Contents for LINZ 108 49
Page 11: ...11 Transportsicherung Kartonpapier entfernen 2 Bild 6...
Page 18: ...18...
Page 19: ...19...
Page 28: ...28 Protection corrugated paper for transportation picture 6 2...
Page 44: ...44 Fig 6 l ment retirer avant la mise en service 2...
Page 60: ...60 Fig 4 Fig 5 Rimuovere carta ondulata di imballaggio Fig 6 2...
Page 82: ...3 M szaki adatok 3 1 M retrajz TYP 108 49 LINZ THYRA...