1.2 Installation
Fuels
Low smoke, trouble-free operation of the stove and a supply of heat at the nominal
level with a chimney draught of 12 Pa are only guaranteed when you use the following
fuels and no others.
Only use natural, dry chopped firewood with a remaining humidity of max. 20%, and
lignite (brown coal) briquettes.
Types of fuels
Heating value appr.
kWh/kg
Brown-coal
Hard wood
Soft wood
5,3 – 5,5
4,0 – 4,2
4,3 – 4,5
With the primary air damper, do you adjust the rated output.
There may be engaged in only the settings and fuel quantities are
given that correspond to your licensed or purchased device.
Adjustment:
Setting of the pri-
mary air regulator
Fuel
6 kW
Setting of the
fuel selector
Burning
time
Warning up,
kindling
D
H
-
Wood
Nominal heating
performance
B
H
ca. 0,75 h
Nominal heating
performance
D
K
ca. 1 h
Brown-coal
Contnuous
combustion
C
K
ca. 4 h
Putting out of working
order
A
K
-
Table 2
The primary regulator knob on ash door, to be set in accordance with Table 1
Pic A (min)
Pic B
Pic C
Pic D
Between 0 and up to the mark infinitely adjustable control knob to the desired per-
formance
Summary of Contents for LINZ 108 49
Page 11: ...11 Transportsicherung Kartonpapier entfernen 2 Bild 6...
Page 18: ...18...
Page 19: ...19...
Page 28: ...28 Protection corrugated paper for transportation picture 6 2...
Page 44: ...44 Fig 6 l ment retirer avant la mise en service 2...
Page 60: ...60 Fig 4 Fig 5 Rimuovere carta ondulata di imballaggio Fig 6 2...
Page 82: ...3 M szaki adatok 3 1 M retrajz TYP 108 49 LINZ THYRA...