25
2
SEP.QE_SEPCOM_SIP-BED-EASY--.M.A3.0722.EN Issue: A3
07.22
4.0 SETTING THE OPERATING PANEL & USE
QE SEPCOM SIP BED EASY
4.2 Reset to factory settings
To reset the PLC to factory settings, follow this procedure:
1. Note down the operation hours and the values set for each parameter by scrolling through the settings pages.
2. Access the “TECHNICAL SETTINGS” by logging in.
3. Scroll through the screens up to
Screen 5
that displays the “factory reset” line.
4. Press “Reset”.
5. The following confirmation window will open:
Press YES to confirm reset to factory settings or press NO to cancel.
After having performed the maintenance required by the system, it is necessary to reset the operation hours of
the related user by pressing on the image of that specific user. Doing so will reset the operation hours counter
to zero.
MANUAL RESTORING OF THE OPERATION HOURS
If the hours counter is reset my mistake, you can restore the counter of the related user by manually entering
the operation hours and the remining time before maintenance is required. Follow the steps indicated below:
4.3 How to reset the operation hours
1)
Tap the box containing the operation hours of the user of interest, below the clock icon;
2)
Use the numeric key to enter the hours value reached by the user;
3)
Tap “Enter” to confirm the values entered.