ANNOTATI
ONS
Viva
GT
VALTIS OGREVANJE d.o.o
34
9.2 Disconnecting the boiler from the hydraulic system
9.2.1 Disconnecting the boiler from the hydraulic network
Disconnect as shown in the picture below:
•
Drain the water from the hydraulic system and disconnect the pipe where marked PV.
•
Disconnect the lifting line where marked TV.
•
Disconnect the return line where marked HV.
HV
HAZARDOUS
•
The boiler should only be
disconnected from the
hydraulic network by a
qualified installer.
TV
PV