3  Transport 

3.1  Packaging  

The  type  of  packaging  depends  on  the  individual  mode  of  shipping.  If  not  separately  contracted,  the 
packaging  is  in  accordance  with  the  rules  and  regulations  of Walther  Systemtechnik  GmbH. This  rule  is  in 
accordance with the Federal Association for Packaging HPE. 

 

3.2  Tasks before Transport 

The following has to be done before transport:  

  Disconnect all power lines.  

The actual transport of the incomplete device and its individual parts requires special care in order to prevent 
damages  from  external  forceful  impact  or  careless  on-  and  off-loading.  Depending  on  the  mode  of 
transportation, suitable transport and load securing has to be selected. The incomplete device will be aligned 
and leveled by appropriate fastening elements

.  

4  Description of Function 

4.1  Purpose of the Incomplete Device  

 

 

CAUTION 

The  use  of  other  media  can  cause  functional  failures,  material  damages  or  even  the 
complete destruction of the device. 

 

The MINI Full-jet Valve 

VMS-08 

is a pneumatically controlled application device for applying liquid media 

such as oils or separating agents. The spraying process is generated by the control air and the material sup-
ply pressure and can be either an intermittent or continuous process.  
 
The control air for opening will be supplied through a pilot valve (

not included in scope of delivery

) and will 

not have a passage in the basic position. Once the pilot valve for the control air receives a signal, the front 
area of the needle piston chamber will be flooded with air; this results in the needle piston pushing back 
against the spring and opening the needle.  
Now the material is discharged from the nozzle. If there is no signal for the pilot valve of the control air, the 
needle will be pushed into the nozzle by the spring in the piston chamber and the spraying device is closed.  
  
Needle function: opened by air pressure / closed by spring pressure.  
Should the control air fail, the valve will be closed by the needle spring.  
The spray medium is supplied to the valve via a pressured container or a pump.  
  

4.2  Technical Data 

Dimensions  

 

 

 

= ca. 64mm x 21mm x27mm (without nozzle) 

Weight   

 

 

 

= ca. 65g 

Control air pressure   

 

 

= 5 

– 7 bar 

Material pressure   

 

 

= max. 3 bar (without closing air) 

Material pressure   

 

 

= max. 15 bar (with closing air) 

 

Custom versions upon request; we reserve the right for technical changes. 

4.3  Type Label  

The type designation is etched in close to the material connection. The serial number is also inscribed in this 
area. 

Summary of Contents for VMS-08

Page 1: ...mber V08 NOTE Please read the Assembly Instructions carefully before first using the incomplete device and strictly adhere to the instructions This incomplete device may only be worked with and worked...

Page 2: ...OF FUNCTION 7 4 1 PURPOSE OF THE INCOMPLETE DEVICE 7 4 2 TECHNICAL DATA 7 4 3 TYPE LABEL 7 5 INITIAL START UP 8 5 1 MOUNTING AND INSTALLATION 8 5 2 HOSE MOUNTING 8 6 OPERATION 9 6 1 GENERAL INFORMATIO...

Page 3: ...Jet Valve VMS 08 Page 3 of 16 Walther Systemtechnik GmbH D 76726 Germersheim Telefon 49 0 7274 7022 0 Telefax 49 0 7274 7022 91 http www walther 2000 de info walther 2000 de 10 5 ARTICLE NUMBERS FOR L...

Page 4: ...Stra e 3 D 76726 Germersheim Description VMS 08 MINI Full Jet Valve Article No V08 We also declare the conformity with other product relevant directives guidelines Mach Direct 2006 42 EU App I Clause...

Page 5: ...warnings are indicated by combinations of text and symbols as follows DANGER Describes a potentially dangerous situation Death grievous bodily harm or severe material damage WILL occur if the respect...

Page 6: ...ve fluids such as acids alkaline solutions cleaning agents chemicals etc In case of doubt please contact the manufacturer 2 5 Incorrect Use Operating the incomplete device with insufficient knowledge...

Page 7: ...device for applying liquid media such as oils or separating agents The spraying process is generated by the control air and the material sup ply pressure and can be either an intermittent or continuo...

Page 8: ...2 Hose Mounting Control air and material will be supplied to the spraying device via two separate connections The following markings are used Control air open black Connection S to 3 2 way magnetic v...

Page 9: ...ond can be reached under appropriate operating conditions material pres sure control air pressure needle stroke short conductions The VMS 08 usually works with a control air pressure of 5 7 bar During...

Page 10: ...pply for atomizer air control air and material Turn off energy supply 7 Taking out of Service 7 1 Short Interruption After short interruptions 15 min and more the valve should be sprayed free prior to...

Page 11: ...y The control air should also be clean and slightly oiled Individual operating conditions and differing media require a minimum and regular routine care 8 2 Cleaning Wash equipment thoroughly after us...

Page 12: ...ng 5 does not get lost Slightly grease new needle 4 and insert into sealing sleeve 3 then clean needle tip from remaining grease Insert new needle 4 together with the sealing sleeve 3 into the main bo...

Page 13: ...ny Phone 49 0 7274 7022 0 Telefax 49 0 7274 7022 91 Email info walther 2000 de Internet www walther 2000 de 9 3 Failures Problem Cause Action Nozzle needle does not open Nozzle needle is sticky within...

Page 14: ...lve VMS 08 Page 14 of 16 Walther Systemtechnik GmbH D 76726 Germersheim Telefon 49 0 7274 7022 0 Telefax 49 0 7274 7022 91 http www walther 2000 de info walther 2000 de 10 Appendix 10 1 Dimensioned Dr...

Page 15: ...8 1 Sealing sleeve complete 4 1 97640041 2 O Ring 4 2 97810097 1 Sealing sleeve 4 3 97640039 2 O Ring 5 0 97113492 1 Nozzle needle complete 5 1 97640039 1 O Ring 6 0 97820007 1 Pressure spring 7 0 976...

Page 16: ...0mm Design and construction of special nozzles needles for your individual application upon request Dwg No Article No Description 1 97211915 Luer Lock Adapter 0 2mm M12 x 0 75 complete 1 97211851 Luer...

Reviews: