Rev. 1.1
Assembly Instructions - MINI-Full-Jet Valve VMS-08
Page 7 of 16
Walther Systemtechnik GmbH
– D 76726 Germersheim
Telefon: +49 (0)7274-7022-0 Telefax: +49 (0)7274-7022-91
http://www.walther-2000.de
3 Transport
3.1 Packaging
The type of packaging depends on the individual mode of shipping. If not separately contracted, the
packaging is in accordance with the rules and regulations of Walther Systemtechnik GmbH. This rule is in
accordance with the Federal Association for Packaging HPE.
3.2 Tasks before Transport
The following has to be done before transport:
Disconnect all power lines.
The actual transport of the incomplete device and its individual parts requires special care in order to prevent
damages from external forceful impact or careless on- and off-loading. Depending on the mode of
transportation, suitable transport and load securing has to be selected. The incomplete device will be aligned
and leveled by appropriate fastening elements
.
4 Description of Function
4.1 Purpose of the Incomplete Device
CAUTION
The use of other media can cause functional failures, material damages or even the
complete destruction of the device.
The MINI Full-jet Valve
VMS-08
is a pneumatically controlled application device for applying liquid media
such as oils or separating agents. The spraying process is generated by the control air and the material sup-
ply pressure and can be either an intermittent or continuous process.
The control air for opening will be supplied through a pilot valve (
not included in scope of delivery
) and will
not have a passage in the basic position. Once the pilot valve for the control air receives a signal, the front
area of the needle piston chamber will be flooded with air; this results in the needle piston pushing back
against the spring and opening the needle.
Now the material is discharged from the nozzle. If there is no signal for the pilot valve of the control air, the
needle will be pushed into the nozzle by the spring in the piston chamber and the spraying device is closed.
Needle function: opened by air pressure / closed by spring pressure.
Should the control air fail, the valve will be closed by the needle spring.
The spray medium is supplied to the valve via a pressured container or a pump.
4.2 Technical Data
Dimensions
= ca. 64mm x 21mm x27mm (without nozzle)
Weight
= ca. 65g
Control air pressure
= 5
– 7 bar
Material pressure
= max. 3 bar (without closing air)
Material pressure
= max. 15 bar (with closing air)
Custom versions upon request; we reserve the right for technical changes.
4.3 Type Label
The type designation is etched in close to the material connection. The serial number is also inscribed in this
area.