8  Maintenance and Repair 

8.1  General Information 

 

CAUTION 

Before  starting  any  maintenance  or  repair  work,  ensure  that  all  air-operated  tools  are 
depressurized and disconnected from the air supply. 
Before opening the spray valve it must be disconnected from the air and fluid supply. 
Otherwise, ejected components can cause injuries. 

 
The full jet valves of the 

VMS-08

 series are high precision tools. Always keep clean and observe minimum 

instructions to maintain a long and useful life of valve. We recommend lubricating moveable parts regularly, 
and  greasing  threads,  especially  the  nozzle  threads,  when  replacing  or  cleaning  the  nozzle.  It  is 
recommended to use clean and filtered application fluid only. The control air should also be clean and slightly 
oiled. Individual operating conditions and differing media require a minimum and regular routine care. 

8.2  Cleaning  

Wash equipment thoroughly after use to remove residues and dirt, especially if needle (pos.5), needle gasket 
(pos.4.2) or nozzle (pos.1) is to be exchanged. 

 

 

IMPORTANT 

Only use soft brushes for outside cleaning of the nozzle tips. Never use metal tools 
with sharp edges! 

 

 

IMPORTANT 

Do not start any repair work on the installed device. Remove the device from the ma-
chines first. (Disconnect from the air and fluid supply!) 

 

8.3  Routine Tasks 

No. 

Description  

Cleaning  

Lubricating   Inspecting  

Additional  

Frequency  

1. 

Connecting lines 

(tightness) 

 

 

 

Monthly  

2. 

Luer-Lock 

X

 

 

X

 

Replace when 

damaged  

Monthly  

 

8.4  Spare Parts 

 

IMPORTANT 
Only use original spare parts from the manufacturer! 
 

Wrong  or  defective  spare  parts  from  other  manufacturers  can  damage  the  device.  If 
other than original spare parts of the manufacturer will be used, all obligations from the 
manufacturer  or  his  sales  partners,  such  as  guarantees,  service  contracts  etc  will  be 

forfeited

 without further notice. 

 

 

Summary of Contents for VMS-08

Page 1: ...mber V08 NOTE Please read the Assembly Instructions carefully before first using the incomplete device and strictly adhere to the instructions This incomplete device may only be worked with and worked...

Page 2: ...OF FUNCTION 7 4 1 PURPOSE OF THE INCOMPLETE DEVICE 7 4 2 TECHNICAL DATA 7 4 3 TYPE LABEL 7 5 INITIAL START UP 8 5 1 MOUNTING AND INSTALLATION 8 5 2 HOSE MOUNTING 8 6 OPERATION 9 6 1 GENERAL INFORMATIO...

Page 3: ...Jet Valve VMS 08 Page 3 of 16 Walther Systemtechnik GmbH D 76726 Germersheim Telefon 49 0 7274 7022 0 Telefax 49 0 7274 7022 91 http www walther 2000 de info walther 2000 de 10 5 ARTICLE NUMBERS FOR L...

Page 4: ...Stra e 3 D 76726 Germersheim Description VMS 08 MINI Full Jet Valve Article No V08 We also declare the conformity with other product relevant directives guidelines Mach Direct 2006 42 EU App I Clause...

Page 5: ...warnings are indicated by combinations of text and symbols as follows DANGER Describes a potentially dangerous situation Death grievous bodily harm or severe material damage WILL occur if the respect...

Page 6: ...ve fluids such as acids alkaline solutions cleaning agents chemicals etc In case of doubt please contact the manufacturer 2 5 Incorrect Use Operating the incomplete device with insufficient knowledge...

Page 7: ...device for applying liquid media such as oils or separating agents The spraying process is generated by the control air and the material sup ply pressure and can be either an intermittent or continuo...

Page 8: ...2 Hose Mounting Control air and material will be supplied to the spraying device via two separate connections The following markings are used Control air open black Connection S to 3 2 way magnetic v...

Page 9: ...ond can be reached under appropriate operating conditions material pres sure control air pressure needle stroke short conductions The VMS 08 usually works with a control air pressure of 5 7 bar During...

Page 10: ...pply for atomizer air control air and material Turn off energy supply 7 Taking out of Service 7 1 Short Interruption After short interruptions 15 min and more the valve should be sprayed free prior to...

Page 11: ...y The control air should also be clean and slightly oiled Individual operating conditions and differing media require a minimum and regular routine care 8 2 Cleaning Wash equipment thoroughly after us...

Page 12: ...ng 5 does not get lost Slightly grease new needle 4 and insert into sealing sleeve 3 then clean needle tip from remaining grease Insert new needle 4 together with the sealing sleeve 3 into the main bo...

Page 13: ...ny Phone 49 0 7274 7022 0 Telefax 49 0 7274 7022 91 Email info walther 2000 de Internet www walther 2000 de 9 3 Failures Problem Cause Action Nozzle needle does not open Nozzle needle is sticky within...

Page 14: ...lve VMS 08 Page 14 of 16 Walther Systemtechnik GmbH D 76726 Germersheim Telefon 49 0 7274 7022 0 Telefax 49 0 7274 7022 91 http www walther 2000 de info walther 2000 de 10 Appendix 10 1 Dimensioned Dr...

Page 15: ...8 1 Sealing sleeve complete 4 1 97640041 2 O Ring 4 2 97810097 1 Sealing sleeve 4 3 97640039 2 O Ring 5 0 97113492 1 Nozzle needle complete 5 1 97640039 1 O Ring 6 0 97820007 1 Pressure spring 7 0 976...

Page 16: ...0mm Design and construction of special nozzles needles for your individual application upon request Dwg No Article No Description 1 97211915 Luer Lock Adapter 0 2mm M12 x 0 75 complete 1 97211851 Luer...

Reviews: