8.5  Replacing Nozzle and Nozzle Needle  

 

 

CAUTION 

Make sure that all connections are depressurized.   

 

 

 

 

Disconnect all connections from energy, pressure and material supply!  

 

Remove/unscrew Luer-Lock adapter (1).  

 

Then unscrew adapter-holder (2).  
(Caution: there is spring pressure at the sealing sleeve (3) and the needle (4))  

 

Carefully pull out sealing sleeve (3) and needle (4).  

 

Make sure that the pressure spring (5) does not get lost. 

 

Slightly grease new needle (4) and insert into sealing sleeve (3); then clean needle tip from remaining 
grease.  

 

Insert new needle (4) together with the sealing sleeve (3) into the main body. Make sure that the pres-
sure spring (5) is located in the correct position.   

 

Screw the adapter-holder (2) into the main body.   

 

Screw in new Luer-Lock adapter (1).  

 

Perform a function test after replacing adapter and needle!  

 

 

CAUTION 

Always replace Luer-Lock adapter (1) and needle (4) at the same time. 

 

 

IMPORTANT 

When reusing nozzles and nozzle needles, these have  to be thoroughly cleaned from 
any sediments or medium residues.  If material remains in the nozzles, this can cause 
leakages in the nozzle-needle system; and nozzle needles with cured medium residues 
can damage the sealing elements in the spraying system. 

 

Summary of Contents for VMS-08

Page 1: ...mber V08 NOTE Please read the Assembly Instructions carefully before first using the incomplete device and strictly adhere to the instructions This incomplete device may only be worked with and worked...

Page 2: ...OF FUNCTION 7 4 1 PURPOSE OF THE INCOMPLETE DEVICE 7 4 2 TECHNICAL DATA 7 4 3 TYPE LABEL 7 5 INITIAL START UP 8 5 1 MOUNTING AND INSTALLATION 8 5 2 HOSE MOUNTING 8 6 OPERATION 9 6 1 GENERAL INFORMATIO...

Page 3: ...Jet Valve VMS 08 Page 3 of 16 Walther Systemtechnik GmbH D 76726 Germersheim Telefon 49 0 7274 7022 0 Telefax 49 0 7274 7022 91 http www walther 2000 de info walther 2000 de 10 5 ARTICLE NUMBERS FOR L...

Page 4: ...Stra e 3 D 76726 Germersheim Description VMS 08 MINI Full Jet Valve Article No V08 We also declare the conformity with other product relevant directives guidelines Mach Direct 2006 42 EU App I Clause...

Page 5: ...warnings are indicated by combinations of text and symbols as follows DANGER Describes a potentially dangerous situation Death grievous bodily harm or severe material damage WILL occur if the respect...

Page 6: ...ve fluids such as acids alkaline solutions cleaning agents chemicals etc In case of doubt please contact the manufacturer 2 5 Incorrect Use Operating the incomplete device with insufficient knowledge...

Page 7: ...device for applying liquid media such as oils or separating agents The spraying process is generated by the control air and the material sup ply pressure and can be either an intermittent or continuo...

Page 8: ...2 Hose Mounting Control air and material will be supplied to the spraying device via two separate connections The following markings are used Control air open black Connection S to 3 2 way magnetic v...

Page 9: ...ond can be reached under appropriate operating conditions material pres sure control air pressure needle stroke short conductions The VMS 08 usually works with a control air pressure of 5 7 bar During...

Page 10: ...pply for atomizer air control air and material Turn off energy supply 7 Taking out of Service 7 1 Short Interruption After short interruptions 15 min and more the valve should be sprayed free prior to...

Page 11: ...y The control air should also be clean and slightly oiled Individual operating conditions and differing media require a minimum and regular routine care 8 2 Cleaning Wash equipment thoroughly after us...

Page 12: ...ng 5 does not get lost Slightly grease new needle 4 and insert into sealing sleeve 3 then clean needle tip from remaining grease Insert new needle 4 together with the sealing sleeve 3 into the main bo...

Page 13: ...ny Phone 49 0 7274 7022 0 Telefax 49 0 7274 7022 91 Email info walther 2000 de Internet www walther 2000 de 9 3 Failures Problem Cause Action Nozzle needle does not open Nozzle needle is sticky within...

Page 14: ...lve VMS 08 Page 14 of 16 Walther Systemtechnik GmbH D 76726 Germersheim Telefon 49 0 7274 7022 0 Telefax 49 0 7274 7022 91 http www walther 2000 de info walther 2000 de 10 Appendix 10 1 Dimensioned Dr...

Page 15: ...8 1 Sealing sleeve complete 4 1 97640041 2 O Ring 4 2 97810097 1 Sealing sleeve 4 3 97640039 2 O Ring 5 0 97113492 1 Nozzle needle complete 5 1 97640039 1 O Ring 6 0 97820007 1 Pressure spring 7 0 976...

Page 16: ...0mm Design and construction of special nozzles needles for your individual application upon request Dwg No Article No Description 1 97211915 Luer Lock Adapter 0 2mm M12 x 0 75 complete 1 97211851 Luer...

Reviews: