background image

Rev. 1.1

 

Assembly Instructions - MINI-Full-Jet Valve VMS-08 

Page 5 of 16 

 

 

 

Walther Systemtechnik GmbH 

– D 76726 Germersheim 

Telefon: +49 (0)7274-7022-0 Telefax: +49 (0)7274-7022-91 
http://www.walther-2000.de 

– [email protected] 

 

1  Introduction  

The MINI full-jet valves of the 

VMS-08 

series  are suitable for the application  of  oils, separating agents  and 

other fluid media where the liquid will be applied as dots or lines. Depending on the viscosity of the applied 
medium, the application pattern can be individually adjusted via the needle stroke. Three hose are employed 
for  supplying  control  air  for  opening,  control  air  for  closing  and  medium. The  full  jet  valves  of  the 

VMS-08

 

series are precision tools. Always keep clean and observe minimum instructions to maintain a long useful life 
of the valve. 

1.1  Target Group of the Assembly Instructions  

  Operating Personnel  

  Maintenance Personnel 

 

1.2  List of Signs and Symbols 

The assembly instructions warn users of operations which may put their health at risk.  
 
The warnings are indicated by combinations of text and symbols as follows: 
 

 

DANGER 

Describes a potentially dangerous situation.  
Death, grievous bodily harm or severe material damage 

WILL

 occur if the respective 

measures of precaution have not been taken

 

 

 

WARNING 

Describes a potentially dangerous situation.  
Death, grievous bodily harm or severe material damage 

MAY

 occur if the respective 

measures of precaution have not been taken.

 

 

 

CAUTION 

Describes a potentially dangerous situation.  
Slight  injuries  CAN  occur  if  the  respective  measures  of  precaution  have  not  been 
taken. This signal word is also used to describe possible property damages.

 

 

 

 

IMPORTANT 

Indicates tips for usage and other particularly useful information. 

No

 dangerous situation.

 

2  Safety 

2.1  General Information  

The  construction  of  this  incomplete  device  is  according  to  the  latest  technology  and  is  absolutely  reliable. 
The  individual  components  as  well  as  the  complete  device  are  continuously  checked  by  our  quality  man-
agement. 

2.2  Dangers from Residual Energy  

Please  instruct  the  operating  personnel  on  the  respective  measures  to  be  taken  against  the  occurrence  of 
mechanical, hydraulic, pneumatic and electric / electronic residual energies. 

Summary of Contents for VMS-08

Page 1: ...mber V08 NOTE Please read the Assembly Instructions carefully before first using the incomplete device and strictly adhere to the instructions This incomplete device may only be worked with and worked...

Page 2: ...OF FUNCTION 7 4 1 PURPOSE OF THE INCOMPLETE DEVICE 7 4 2 TECHNICAL DATA 7 4 3 TYPE LABEL 7 5 INITIAL START UP 8 5 1 MOUNTING AND INSTALLATION 8 5 2 HOSE MOUNTING 8 6 OPERATION 9 6 1 GENERAL INFORMATIO...

Page 3: ...Jet Valve VMS 08 Page 3 of 16 Walther Systemtechnik GmbH D 76726 Germersheim Telefon 49 0 7274 7022 0 Telefax 49 0 7274 7022 91 http www walther 2000 de info walther 2000 de 10 5 ARTICLE NUMBERS FOR L...

Page 4: ...Stra e 3 D 76726 Germersheim Description VMS 08 MINI Full Jet Valve Article No V08 We also declare the conformity with other product relevant directives guidelines Mach Direct 2006 42 EU App I Clause...

Page 5: ...warnings are indicated by combinations of text and symbols as follows DANGER Describes a potentially dangerous situation Death grievous bodily harm or severe material damage WILL occur if the respect...

Page 6: ...ve fluids such as acids alkaline solutions cleaning agents chemicals etc In case of doubt please contact the manufacturer 2 5 Incorrect Use Operating the incomplete device with insufficient knowledge...

Page 7: ...device for applying liquid media such as oils or separating agents The spraying process is generated by the control air and the material sup ply pressure and can be either an intermittent or continuo...

Page 8: ...2 Hose Mounting Control air and material will be supplied to the spraying device via two separate connections The following markings are used Control air open black Connection S to 3 2 way magnetic v...

Page 9: ...ond can be reached under appropriate operating conditions material pres sure control air pressure needle stroke short conductions The VMS 08 usually works with a control air pressure of 5 7 bar During...

Page 10: ...pply for atomizer air control air and material Turn off energy supply 7 Taking out of Service 7 1 Short Interruption After short interruptions 15 min and more the valve should be sprayed free prior to...

Page 11: ...y The control air should also be clean and slightly oiled Individual operating conditions and differing media require a minimum and regular routine care 8 2 Cleaning Wash equipment thoroughly after us...

Page 12: ...ng 5 does not get lost Slightly grease new needle 4 and insert into sealing sleeve 3 then clean needle tip from remaining grease Insert new needle 4 together with the sealing sleeve 3 into the main bo...

Page 13: ...ny Phone 49 0 7274 7022 0 Telefax 49 0 7274 7022 91 Email info walther 2000 de Internet www walther 2000 de 9 3 Failures Problem Cause Action Nozzle needle does not open Nozzle needle is sticky within...

Page 14: ...lve VMS 08 Page 14 of 16 Walther Systemtechnik GmbH D 76726 Germersheim Telefon 49 0 7274 7022 0 Telefax 49 0 7274 7022 91 http www walther 2000 de info walther 2000 de 10 Appendix 10 1 Dimensioned Dr...

Page 15: ...8 1 Sealing sleeve complete 4 1 97640041 2 O Ring 4 2 97810097 1 Sealing sleeve 4 3 97640039 2 O Ring 5 0 97113492 1 Nozzle needle complete 5 1 97640039 1 O Ring 6 0 97820007 1 Pressure spring 7 0 976...

Page 16: ...0mm Design and construction of special nozzles needles for your individual application upon request Dwg No Article No Description 1 97211915 Luer Lock Adapter 0 2mm M12 x 0 75 complete 1 97211851 Luer...