5.1.  Grease separator WNG-1/2/3

Grease separator for mobile rinsing facilities

The grease separators for mobile rinsing facilities are intended for use under the following conditions:

• 

Connection of a commercial dishwasher with a maximum water requirement of 5 liters per wash cycle and a wash 

time of at least 1 minute.

• 

In addition to a dishwasher, connection to at most one device for pre-washing the dishes and brief operation

A grease trap is used wherever greasy wastewater is to be expected. The grease separator separates fats, oils and sludge 

from the wastewater.

5.2.  Specifications of the grease separator

Type WNG-1 - For drawings and details, see licneces from page 11

Sludge trap

10 Liter

Grease separation capacity

20 Liter

Certificate

Z-54.6-340-

Outer dimensions (wxdxh in mm)

655 x 340 x 316

Weight

20kg

Typ WNG-2  - For drawings and details, see licneces from page 11

Sludge trap

16 Liter

Grease separation capacity

44 Liter

Certificate

Z-54.6-340-

Outer dimensions (wxdxh in mm)

730 x 413 x 409

Weight

35kg

Typ WNG-3 - For drawings and details, see licneces from page 11

Sludge trap

52 Liter

Grease separation capacity

132 Liter

Certificate

Z-54.6-340-

Outer dimensions (wxdxh in mm)

900 x 540 x 629

Weight

60kg

5.3.  Intended Use

The separator system is intended exclusively for the separation of saponifiable oils and fats of vegetable and animal origin. 

Any use going beyond this is considered improper. The manufacturer is not liable for any resulting damage; the user alone 

bears the risk!

Animal and vegetable oils and fats must not be discharged into public waste disposal facilities or waters, as they cause 

cross-sectional constrictions and blockages in the disposal lines when cold. Furthermore, after a short decomposition 

time, fatty acids are formed, which lead to unpleasant odors and attack pipes and structures in the drainage system. The 

solidified layer of fat on the surface of the water also inhibits the necessary oxygen supply in waters and sewage treatment 

plants. In addition, DIN1986 Part 1 requires the retention of harmful substances. For these reasons, grease separator sys-

tems must be provided that must be disposed of accordingly. The temperature in the separator should be as low as possib-

le. With an increase of 10 ° C the separation efficiency is halved. 

Compliance with the operating, maintenance and repair conditions prescribed by the manufacturer is also part of the inten-

ded use

6.  Installation / Operation

See licneces from page 11.

Summary of Contents for WNG-1

Page 1: ...Version 6 2 B10 Grease separator WNG 1 2 3 Installation and operating instructions incl DIBT Licence...

Page 2: ...e 5 4 Delivery transport storage 5 5 Description 6 5 1 Grease separator WNG 1 2 3 6 5 2 Specifications of the grease separator 6 5 3 Intended Use 6 6 Installation Operation 6 6 1 Additional maintenanc...

Page 3: ...turer or plant constructor The grease separator may only be used if it is in perfect condition The generally prescribed electrical and mechanical protective devices must be provided During assembly el...

Page 4: ...s The individual actions and qualifications can be found in Table 1 Qualification Danger Untrained unqualified or untrained personnel must not operate the machine system The personnel for operation ma...

Page 5: ...ase separator see 2 4 Personal protective equipment Never step under a suspended load It must be ensured that nobody is under a suspended load Delivery Every grease separator leaves our factory in a m...

Page 6: ...132 Liter Certificate Z 54 6 340 Outer dimensions wxdxh in mm 900 x 540 x 629 Weight 60kg 5 3 Intended Use The separator system is intended exclusively for the separation of saponifiable oils and fat...

Page 7: ...he grease separator system must not be exceeded After filling up with fresh water the device can be put into operation Only wastewater with vegetable and animal fats or oils may be fed into the grease...

Page 8: ...nd or fat and wear suitable footwear Risk of infection in contact with sewage The wastewater contains bacteria There is a risk of infection if it comes into contact with mucous membranes eyes wounds o...

Page 9: ...of the separator and the sludge trap is not exceeded Unless otherwise requirde by ordinances and other requirements cleaning and maintenance must be carried out in accor dance with the operating inst...

Page 10: ...nie 2006 42 EG Kennzeichnung 93 68 EWG BER2006 Note area of application The designated grease separator systems are intended for the separation of solid and liquid organic fats oils from waste water b...

Page 11: ...a e 13 45891 Gelsenkirchen Fettabscheider aus Edelstahl f r bewegliche Sp leinrichtungen WNG Der oben genannte Regelungsgegenstand wird hiermit allgemein bauaufsichtlich zugelassen genehmigt Dieser Be...

Page 12: ...chten 2 2 1 3 Einbauteile Alle Einbauteile sind gem den Angaben der Anlagen 1 bis 3 in Verantwortung des Antrag stellers herzustellen und in die Abscheiderbeh lter einzubauen 2 2 2 Kennzeichnung Die A...

Page 13: ...gigen DIN Normen keine Toleranzen vorgegeben sind gilt f r Bauteilma e Genauigkeitsgrad B nach DIN EN ISO 13920 3 f r Gef lle 10 mm als Basisma gilt der Ruhewasserspiegel f r brige Funktionsma e 1 5 a...

Page 14: ...ttabscheider aus Edelstahl f r bewegliche Sp leinrichtungen WNG Ma e WNG 1 WNG 2 und WNG 3 Anlage 2 Allgemeine bauaufsichtliche Zulassung Allgemeine Bauartgenehmigung Nr Z 54 6 340 vom 30 August 2021...

Page 15: ...r Zu und Ablaufleitungen ist die Anlage auf Sch den Dichtigkeit und freien Durchgang zu pr fen Ersteinsatz Vor dem ersten Einsatz sind der Schlamm und Fettabscheideraum so lange mit Wasser aufzuf llen...

Page 16: ...ww eu...

Reviews: