background image

5

2.5.  Foreseeable misuse

• 

The grease separator may only be operated by someone who has read and understood the operating manual.

• 

People who are under medication or other drugs are not allowed to operate or maintain the system or perform any 

other work on it.

3.  Guarantee 

See AGB Walpol Katalog or go to our website: www.walpol.eu

Unauthorized changes to the machine exclude any liability on the part of the manufacturer for any resulting damage. If the 

machine is operated improperly, not as intended or by untrained personnel, the following dangers may arise:

• 

Danger to life

• 

Danger to the machine and other assets of the owner,

• 

Danger to the efficient work of the machine

To assert warranty claims, the products must be properly connected and operated and used in accordance with the data 

sheets. A prerequisite is a fully completed operating diary, which can be requested from Walpol in the event of a warranty 

claim. The operating log is part of this document, the maintenance plan must be created by the operator.

4.  Delivery, transport, storage

Securitynote:

Warning: Suspended loads

• 

Protective equipment must be worn for all work in the vicinity of the grease separator, see 2.4 Personal protective 

equipment,

• 

Never step under a suspended load.

• 

It must be ensured that nobody is under a suspended load.

Delivery

Every grease separator leaves our factory in a mechanically perfect condition. It is recommended to transport the grease 

separator in its original packaging to the installation site.

Check delivery

• 

Check the packaging for transport damage. Any damage must be noted in the cargo register.

• 

Check whether the delivery is complete.

Unpacking

Warning

When removing the transport packaging, there is a risk of damage from sharp edges, nails, staples, splinters, etc.
• 

Carefully unpack the grease separator.

• 

Check the grease separator for obvious transport damage.

• 

Do not remove the packaging until shortly before installation.

• 

Protective equipment must be worn for all work in the vicinity of the grease separator, see 2.2 Personal protec-

tive equipment

Transport

Securitynote:

Caution: Careless loading or unloading can damage the grease separator.

• 

Carry out loading or unloading carefully.

• 

Use lifting equipment suitable for the load.

• 

Observe the transport arrows on the packaging.

• 

The packaging serves only as transport protection and must not be used for lifting. 

Storage

• 

Store the grease separator in the original packaging in a dry, dust-free place that is protected from weather effects.

• 

Avoid extreme heat or cold.

Summary of Contents for WNG-1

Page 1: ...Version 6 2 B10 Grease separator WNG 1 2 3 Installation and operating instructions incl DIBT Licence...

Page 2: ...e 5 4 Delivery transport storage 5 5 Description 6 5 1 Grease separator WNG 1 2 3 6 5 2 Specifications of the grease separator 6 5 3 Intended Use 6 6 Installation Operation 6 6 1 Additional maintenanc...

Page 3: ...turer or plant constructor The grease separator may only be used if it is in perfect condition The generally prescribed electrical and mechanical protective devices must be provided During assembly el...

Page 4: ...s The individual actions and qualifications can be found in Table 1 Qualification Danger Untrained unqualified or untrained personnel must not operate the machine system The personnel for operation ma...

Page 5: ...ase separator see 2 4 Personal protective equipment Never step under a suspended load It must be ensured that nobody is under a suspended load Delivery Every grease separator leaves our factory in a m...

Page 6: ...132 Liter Certificate Z 54 6 340 Outer dimensions wxdxh in mm 900 x 540 x 629 Weight 60kg 5 3 Intended Use The separator system is intended exclusively for the separation of saponifiable oils and fat...

Page 7: ...he grease separator system must not be exceeded After filling up with fresh water the device can be put into operation Only wastewater with vegetable and animal fats or oils may be fed into the grease...

Page 8: ...nd or fat and wear suitable footwear Risk of infection in contact with sewage The wastewater contains bacteria There is a risk of infection if it comes into contact with mucous membranes eyes wounds o...

Page 9: ...of the separator and the sludge trap is not exceeded Unless otherwise requirde by ordinances and other requirements cleaning and maintenance must be carried out in accor dance with the operating inst...

Page 10: ...nie 2006 42 EG Kennzeichnung 93 68 EWG BER2006 Note area of application The designated grease separator systems are intended for the separation of solid and liquid organic fats oils from waste water b...

Page 11: ...a e 13 45891 Gelsenkirchen Fettabscheider aus Edelstahl f r bewegliche Sp leinrichtungen WNG Der oben genannte Regelungsgegenstand wird hiermit allgemein bauaufsichtlich zugelassen genehmigt Dieser Be...

Page 12: ...chten 2 2 1 3 Einbauteile Alle Einbauteile sind gem den Angaben der Anlagen 1 bis 3 in Verantwortung des Antrag stellers herzustellen und in die Abscheiderbeh lter einzubauen 2 2 2 Kennzeichnung Die A...

Page 13: ...gigen DIN Normen keine Toleranzen vorgegeben sind gilt f r Bauteilma e Genauigkeitsgrad B nach DIN EN ISO 13920 3 f r Gef lle 10 mm als Basisma gilt der Ruhewasserspiegel f r brige Funktionsma e 1 5 a...

Page 14: ...ttabscheider aus Edelstahl f r bewegliche Sp leinrichtungen WNG Ma e WNG 1 WNG 2 und WNG 3 Anlage 2 Allgemeine bauaufsichtliche Zulassung Allgemeine Bauartgenehmigung Nr Z 54 6 340 vom 30 August 2021...

Page 15: ...r Zu und Ablaufleitungen ist die Anlage auf Sch den Dichtigkeit und freien Durchgang zu pr fen Ersteinsatz Vor dem ersten Einsatz sind der Schlamm und Fettabscheideraum so lange mit Wasser aufzuf llen...

Page 16: ...ww eu...

Reviews: