12
WDC200-NX Electronic Water Management.
Revision-2
D
Input from Room 1
Basin/Bath hot piezo
touch button
User input (piezo button or IR sensor) for
Room 1 hot Basin/Bath
E
Input from Room 2 WC
Flush piezo touch button
User input (piezo button or IR sensor) for
Room 2 WC Flush
F
Input from Room 2
Shower piezo touch
button
User input (piezo button or IR sensor) for
Room 2 Shower
G
Input from Room 2
Basin/Bath cold piezo
touch button
User input (piezo button or IR sensor) for
Room 2 cold Basin/Bath
H
Input from Room 2
Basin/Bath hot piezo
touch button
User input (piezo button or IR sensor) for
Room 2 hot Basin/Bath
I
Room 1 Auxiliary 1
Input to clear Room 1 Lockouts
J
Room 2 Auxiliary 1
Input to clear Room 2 Lockouts
K
Room 1 Auxiliary 2
Input to start/stop Room 1 Commissioning
Purge
L
Room 2 Auxiliary 2
Input to start/stop Room 2 Commissioning
Purge
M
Room 1 Auxiliary 3
Input to set Room 1 Remote L.O.
N
Room 2 Auxiliary 3
Input to set Room 2 Remote L.O.
O
Room 1 Auxiliary 4
Input for Room 1 WC Remote Flush
P
Room 2 Auxiliary 4
Input for Room 2 WC Remote Flush
CAN
CAN Link Sockets
CAN port connections to interface with
external control devices e.g. WEX300
LAN
Network Link Socket
LAN connection to WDCMS
Screened Ethernet Cable to be used.
POWER
Power cable connection
Electrical power supply cable 2 metre in
length
There are six types of sockets in the control unit:
•
8x 3 pin XLR output sockets (1 To 8), to connect the unit to the
solenoid valves.
•
16x 3.5 mm input sockets (A to P), for Piezo touch buttons & aux
inputs.
•
1x RJ45 connector to connect the control unit to the LAN
•
2x RJ11 connectors to connect CAN bust expansion modules
•
1x IEC C7 power connection
•
1x USB Type-B Mini for firmware updates and configuration
upload/download
The socket and plug assignments are fully configurable. Controllers will be pre-
configured with default settings.