1.  INTRODUCTION. 

 

 

1. INTRODUCTION. 

(a) Welcome to the hand wash drier unit. This unit has been designed and constructed from 

quality materials to a high standard. The handwash unit can only be installed in a frost-
free or frost protected environment to avoid damage due to freezing pipes. All water 
supply pipes to & within the handwash must be suitably insulated from freezing. 
 

(b) Contained within the packing box in addition to these instructions is: 

1 x CME hand wash drier unit,  

2 x Installation mounting plates fitted with unit fixing bolts & adjustment nuts,  

1 x drawer lock key, 1 x soap liquid (2.5ltr), 

1 x Product Manual. 

(c) Technically qualified staff should carry out the following instructions. If you have any 

further queries about installing or commissioning the handwash unit, help should be 
obtained from Wallgate Ltd using the contact details on the front page here. 

(d) Details on how to use, care for and service the hand wash unit are contained in the 

Operating & Maintenance section of this manual

 

2.SITE PREPARATION. 

(a) Prepare an opening in the wall surface, accurate to the dimensions shown in drawing 

“INSCME_45” on page 4. It is important that the aperture is square and within tolerance to 
the stated dimensions as there is very little overlap of the unit fascia (approx 10mm). If 
preferable the unit could be fitted as the block work proceeds and a timber lining will also 
greatly improve the aperture accuracy. In existing buildings it may be preferable to build a 
stud wall to house the unit as an alternative to preparing an aperture in the wall. 

(b) The unit is held between two metal mounting plates that are fixed to each side of the 

aperture. If support is required above the aperture then a suitable lintel must be installed. 

(c) Complete all surface finishes (i.e. screed, plaster or tiling) to the wall before fixing the 

mounting brackets, as these must be fitted flush with the finished surface. 

(d) An electrical supply should be provided with a switched fused spur-13Amp, double pole 

connection point that is local to the unit (the contact separation of the fused spur switch 
should be at least 3mm). A suitable cable with a minimum conductor size of 1.5mm sq. 
should be connected to the fused spur switch ready for connection to the unit. 

(e) A mains cold water supply with a min pressure of 1.75bar should be provided within the 

wall cavity below the aperture and terminated with a suitable isolating tap. Final 
connection to the handwash unit water inlet (15mm compression) may be made with a 
flexible mains rated (WRC approved) hose. If the unit is to be connected to a gravity 
(tank) fed supply further advice should be requested from Wallgate. 

(f)  A waste outlet connection of 32mm (1¼”) should be provided within the wall cavity below 

the aperture. 

 

3. APPLIANCE PREPARATION & FITTING. 

(a) Remove the unit mounting plates from the packing box. They are packed inside plastic 

bubble & placed to one side on top of the handwash unit. 

(b) Fit the mounting brackets to the aperture sides ensuring that they are perfectly level 

horizontally & vertically with each other. Screw holes are provided on each plate to secure 
them, ensure that the screws are of a suitable size (No 10 x 30mm long minimum). 
Remove the four unit fixing bolts & washers from the mounting plates & retain in a safe 
place. Do not remove the brass nuts fitted to the bushes on the plates but ensure that 
they are fully screwed onto each bush hand tight only. 

(c) The unit should not be lifted out of the packing box. Instead, cut down each of the box 

corners and lay the sides down flat. Remove the pack containing the keys & retain in a 

Handwash Installation & Commissioning 

Instructions for CME model. 

Summary of Contents for CME 41

Page 1: ...ts Contact our Customer Services Department Tel 01722 744594 Fax 01722 742096 Sales or 742933 Service Email sales wallgate com service wallgate com Crow Lane Wilton Salisbury Wiltshire SP2 OHB www wallgate com Hand Wash Drier Models CME_41 45 Product Manual CME_45 ...

Page 2: ...st be installed c Complete all surface finishes i e screed plaster or tiling to the wall before fixing the mounting brackets as these must be fitted flush with the finished surface d An electrical supply should be provided with a switched fused spur 13Amp double pole connection point that is local to the unit the contact separation of the fused spur switch should be at least 3mm A suitable cable w...

Page 3: ...et sides in too far which will then prevent the satisfactory operation of the drawer in its slides The cabinet sides should be set apart a distance of 541mm 21 5 16 to their outer edges Once all four points are set press the unit fully into the aperture and tighten the four bolts 4 ELECTRICAL CONNECTION WARNING This appliance must be earthed a The CME is designed for a fixed wire type installation...

Page 4: ...bove the basin The isolator switch should illuminate red f To check that the unit operates and to complete the final set up procedures now refer to the Operating Maintenance Instructions sections 3 2 4 in this order g On completion of the above replace the top fascia panel and lock the lower drawer The following items should be passed to the customer 1 off lower drawer key this Product Manual 7 TE...

Page 5: ......

Page 6: ...over due to the risk of electric shock For the CME 41 push button operated model follow the instructions below For soap dispensing press the hand or foot button marked SOAP Dosage depends entirely on the number of times the button is pressed The electric type pump runs for a pre set time 0 3 seconds to deliver approximately 5ml of soap This can only be adjusted by consulting the manufacturer The s...

Page 7: ...with one of two electronic controllers TCU041 or TCU100 which is mounted towards the top inside face of the handwash housing The TCU041 controller is used on units with just soap water and air functions push button operated The time settings may be adjusted by following the adjacent instructions The TCU100 is fitted to the CME_45 model time cycles may be adjusted using the onboard Control Interfac...

Page 8: ...will only operate the water heater when the flow rate is set above 1 2ltr min 5 MAINTAINANCE Wallgate operates a comprehensive service package details of which can be obtained from our After Sales Service department A full spare parts facility is also available WARNING The water heater is an open outlet type and under no circumstances should the water outlet nozzle be allowed to become blocked or ...

Reviews: