background image

For the CME-45 model, IR sensor operated, follow the instructions below: 

When you place your hands into the wash basin an automatic cycle shall commence as per 
the sequence now detailed: 
 

  Soap dispensing for 0.3 second. 

  Followed by a delay of 1 second. 

  Warm Water for 12 seconds. 

  Followed by a delay of 1 second. 

  Air drying for 35 seconds. 

  Followed by a delay of 3 seconds after which another cycle can then be activated. 

 

Note that another cycle shall not start unless your hands or any other item in the sensor 
detection zone/range is removed momentarily. 

 

Time Cycle Adjustments. 

 

To adjust the time cycle settings for water and air dispensing, access must be made into the 
cabinet behind the unit upper fascia panel, a RSIST-TORX key is required to remove the two 
screws securing the panel. An internal cover plate is mounted behind the upper front fascia 
panel. It is recommended that only qualified personnel carry out inspection/adjustments due 
to  the  risk  of  electric  shock  if  the  appropriate 
precautions  are  not  taken.  Switch  OFF  the 
electrical supply at the fused spur or mains switch 
board. 

 

To the left of the internal cover plate, switch OFF 
the  “Electrical  Isolator”  to  ensure  the  electrical 
supply to the unit remains disconnected. Remove 
the  inner  cover  plate  by  releasing  the  screws 
securing it and then ease it out from the unit. 
 
The  handwash  will  be  fitted  with  one  of  two 
electronic controllers, (TCU041 or TCU100) which 
is  mounted  towards  the  top  inside  face  of  the 
handwash  housing.  The  TCU041  controller  is 
used  on  units  with  just  soap,  water  and  air 
functions,  push  button  operated.  The  time 
settings  may  be  adjusted  by  following  the 
adjacent  instructions.  The  TCU100  is  fitted  to  the  CME_45  model,  time  cycles  may  be 
adjusted using the onboard ‘Control Interface module’. For further details contact Wallgate.  

 

After all adjustments are completed ensure that the internal cover plate is correctly replaced 
& that the switch Electrical Isolator is in the ON position (Red light illuminated).  Replace & 
secure the upper front fascia panel with the two security screws. 

 

3. REPLENISHING THE SOAP 

a)  Open the lower drawer with the keys provided, and remove the soap container lid. Refill 

the  container  to  the  MAX  level  mark  avoiding  any  accidental  spillage.  Replace  the 
container  lid  ensuring  that  the  tubing  is  inserted  fully  into  the  container.  The 
recommended  soap  for  use  in  this  unit  is  a  free  flowing  liquid  soap.  It  is  particularly 
important  that  creams  or  gels  are  NOT  used,  as  this  will  cause  a  blockage.  The 
recommended soap and its specification is available from Wallgate Ltd. 

b)  To prime the unit with soap for models with button operation push the soap button several 

times  until  the  soap  comes  through  the  dispensing  nozzle.  For  automatic  units  a  prime 
switch  is  fitted  and  is  located  in  the  drawer  with  the  soap  container.  When  the  prime 
switch  is pressed it  will operate the pump. Press it until the system is primed. Problems 

 

Summary of Contents for CME 41

Page 1: ...ts Contact our Customer Services Department Tel 01722 744594 Fax 01722 742096 Sales or 742933 Service Email sales wallgate com service wallgate com Crow Lane Wilton Salisbury Wiltshire SP2 OHB www wallgate com Hand Wash Drier Models CME_41 45 Product Manual CME_45 ...

Page 2: ...st be installed c Complete all surface finishes i e screed plaster or tiling to the wall before fixing the mounting brackets as these must be fitted flush with the finished surface d An electrical supply should be provided with a switched fused spur 13Amp double pole connection point that is local to the unit the contact separation of the fused spur switch should be at least 3mm A suitable cable w...

Page 3: ...et sides in too far which will then prevent the satisfactory operation of the drawer in its slides The cabinet sides should be set apart a distance of 541mm 21 5 16 to their outer edges Once all four points are set press the unit fully into the aperture and tighten the four bolts 4 ELECTRICAL CONNECTION WARNING This appliance must be earthed a The CME is designed for a fixed wire type installation...

Page 4: ...bove the basin The isolator switch should illuminate red f To check that the unit operates and to complete the final set up procedures now refer to the Operating Maintenance Instructions sections 3 2 4 in this order g On completion of the above replace the top fascia panel and lock the lower drawer The following items should be passed to the customer 1 off lower drawer key this Product Manual 7 TE...

Page 5: ......

Page 6: ...over due to the risk of electric shock For the CME 41 push button operated model follow the instructions below For soap dispensing press the hand or foot button marked SOAP Dosage depends entirely on the number of times the button is pressed The electric type pump runs for a pre set time 0 3 seconds to deliver approximately 5ml of soap This can only be adjusted by consulting the manufacturer The s...

Page 7: ...with one of two electronic controllers TCU041 or TCU100 which is mounted towards the top inside face of the handwash housing The TCU041 controller is used on units with just soap water and air functions push button operated The time settings may be adjusted by following the adjacent instructions The TCU100 is fitted to the CME_45 model time cycles may be adjusted using the onboard Control Interfac...

Page 8: ...will only operate the water heater when the flow rate is set above 1 2ltr min 5 MAINTAINANCE Wallgate operates a comprehensive service package details of which can be obtained from our After Sales Service department A full spare parts facility is also available WARNING The water heater is an open outlet type and under no circumstances should the water outlet nozzle be allowed to become blocked or ...

Reviews: