6. COMMISSIONING FOR USE.
(a) Replace the drawer into its slides ensuring it engages properly on each side into the clips.
(b) Place the soap container into the right hand side of the drawer & fill it with the soap
provided.
(c) Open fully the water supply tap & the plastic tap/flow regulator on the unit. Check the
system for any leaks.
(d) Replace the top internal metal cover with the three screw’s, under no circumstances
should the unit be operated without this cover fitted.
(e) Switch “ON” the electrical supply at the spur connection point & then on the unit at the
isolator switch (Positioned on the front left-hand side above the basin). The isolator switch
should illuminate red.
(f) To check that the unit operates and to complete the final set-up procedures now refer to
the “Operating & Maintenance Instructions”, sections 3, 2 & 4 in this order.
(g) On completion of the above, replace the top fascia panel and lock the lower drawer. The
following items should be passed to the customer: 1 off lower drawer key, this "Product
Manual”.
7. TECHNICAL DATA.
(a) Electrical supply:
220 / 230 240v ac 50Hz single phase.
Maximum rating: 220v – 2650watts / 230v – 2850watts / 240v – 3100watts.
WARNING THIS APPLIANCE MUST BE EARTHED.
(b) Water supply:
Thermal cut out 46
°
C (+/- 3).
Temp of water for flow rates 1.2 – 1.6 l/min, 35
°
C - 45
°
C. (Typically with ambient @
15
°
C).
Nominal pressure range, 1.75 – 10bar.
Cold water feed
∅
15mm copper.
(c) Waste,
∅
1 ¼” (32mm) pipe (internal), connection to 1 ¼” BSP sink waste.