background image

 

6. COMMISSIONING FOR USE. 

(a) Replace the drawer into its slides ensuring it engages properly on each side into the clips. 
(b) Place the soap container into the right hand side of the drawer & fill it with the soap 

provided. 

(c) Open fully the water supply tap & the plastic tap/flow regulator on the unit. Check the 

system for any leaks. 

(d) Replace the top internal metal cover with the three screw’s, under no circumstances 

should the unit be operated without this cover fitted. 

(e) Switch “ON” the electrical supply at the spur connection point & then on the unit at the 

isolator switch (Positioned on the front left-hand side above the basin). The isolator switch 
should illuminate red. 

(f)  To check that the unit operates and to complete the final set-up procedures now refer to 

the “Operating & Maintenance Instructions”, sections 3, 2 & 4 in this order. 

(g) On completion of the above, replace the top fascia panel and lock the lower drawer. The 

following items should be passed to the customer: 1 off lower drawer key, this "Product 
Manual”. 

 

7. TECHNICAL DATA. 

(a) Electrical supply: 

  220 / 230 240v ac 50Hz single phase. 

  Maximum rating: 220v – 2650watts / 230v – 2850watts / 240v – 3100watts. 

  WARNING THIS APPLIANCE MUST BE EARTHED. 

(b) Water supply: 

  Thermal cut out 46

°

C (+/- 3). 

  Temp of water for flow rates 1.2 – 1.6 l/min, 35

°

C - 45

°

C. (Typically with ambient @ 

15

°

C). 

  Nominal pressure range, 1.75 – 10bar. 

  Cold water feed 

15mm copper. 

(c)  Waste, 

 1 ¼” (32mm) pipe (internal), connection to 1 ¼” BSP sink waste. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

Summary of Contents for CME 41

Page 1: ...ts Contact our Customer Services Department Tel 01722 744594 Fax 01722 742096 Sales or 742933 Service Email sales wallgate com service wallgate com Crow Lane Wilton Salisbury Wiltshire SP2 OHB www wallgate com Hand Wash Drier Models CME_41 45 Product Manual CME_45 ...

Page 2: ...st be installed c Complete all surface finishes i e screed plaster or tiling to the wall before fixing the mounting brackets as these must be fitted flush with the finished surface d An electrical supply should be provided with a switched fused spur 13Amp double pole connection point that is local to the unit the contact separation of the fused spur switch should be at least 3mm A suitable cable w...

Page 3: ...et sides in too far which will then prevent the satisfactory operation of the drawer in its slides The cabinet sides should be set apart a distance of 541mm 21 5 16 to their outer edges Once all four points are set press the unit fully into the aperture and tighten the four bolts 4 ELECTRICAL CONNECTION WARNING This appliance must be earthed a The CME is designed for a fixed wire type installation...

Page 4: ...bove the basin The isolator switch should illuminate red f To check that the unit operates and to complete the final set up procedures now refer to the Operating Maintenance Instructions sections 3 2 4 in this order g On completion of the above replace the top fascia panel and lock the lower drawer The following items should be passed to the customer 1 off lower drawer key this Product Manual 7 TE...

Page 5: ......

Page 6: ...over due to the risk of electric shock For the CME 41 push button operated model follow the instructions below For soap dispensing press the hand or foot button marked SOAP Dosage depends entirely on the number of times the button is pressed The electric type pump runs for a pre set time 0 3 seconds to deliver approximately 5ml of soap This can only be adjusted by consulting the manufacturer The s...

Page 7: ...with one of two electronic controllers TCU041 or TCU100 which is mounted towards the top inside face of the handwash housing The TCU041 controller is used on units with just soap water and air functions push button operated The time settings may be adjusted by following the adjacent instructions The TCU100 is fitted to the CME_45 model time cycles may be adjusted using the onboard Control Interfac...

Page 8: ...will only operate the water heater when the flow rate is set above 1 2ltr min 5 MAINTAINANCE Wallgate operates a comprehensive service package details of which can be obtained from our After Sales Service department A full spare parts facility is also available WARNING The water heater is an open outlet type and under no circumstances should the water outlet nozzle be allowed to become blocked or ...