![background image](http://html2.mh-extra.com/html/wallas/26cc/26cc_installation-manual_3236326062.webp)
Maintenance
The glow plug does not
receive sufficient current.
(The glow plug does not heat
up to a sufficient
temperature.)
Check the power cord
connections, joints and the
main switch.
Low fuel quality.
Change the fuel.
Check the battery voltage.
Water in the fuel.
Dewater the fuel or replace it.
Water in the flue gas hose.
Check the bends and loops
of the flue gas hose for water
(water trap).
The device
smokes when
started up.
Check the battery voltage.
The battery voltage under
load must be at least
10.7 V
Water in the fuel.
Dewater the fuel or replace it.
Water in the flue gas hose.
The fuel has run out or its
level is too low for the intake
hose in the tank to reach it.
Check the bends and loops
of the flue gas hose for water
(water trap).
Add fuel.
The device goes
out during use.
The burner is sooty.
The burner must be opened
and cleaned.
Check the condition of the
battery and the electrical
cables/connectors.
Charge the battery, if
necessary.
The burner has overheated.
Check air circulation around
the device.
High wind pressure at the
flue gas lead-through's side.
Ensure that the wind does
not blow directly in the lead-
through.
2.0.3_GB
en
26CC / 40CC
D80151
- 62 -
490525C
Summary of Contents for 26CC
Page 12: ...12 D80150 Tekniset tiedot Toimintaperiaate fi 26CC 40CC P 12 V 490525C...
Page 40: ...Technical information Operating principles en 26CC 40CC D80151 40 P 12 V 490525C...
Page 68: ...Teknisk information Driftsprinciper sv 26CC 40CC D80152 68 P 12 V 490525C...