![background image](http://html2.mh-extra.com/html/wallas/26cc/26cc_installation-manual_3236326059.webp)
*
)
RELEASING THE LOCK:
1. Switch off the main power as the lights blink.
2. Switch the main power back on.
3. Press the power switch (for at least 2 s). The yellow current indi-
cator will light for 1-3 seconds.
4. When the yellow current indicator light has gone out, press the
power switch again (for at least 2 seconds). The device is turned
off.
5. Restart the device normally.
Troubleshooting
If the device has locked itself, you must determine the cause for the
locking before releasing it.
Maintenance
Fault signals and releasing the lock
en
Yellow
Yellow
Yellow
Yellow
Yellow
Red
Red
Red
Colour
Glow failure
Combustion air blower fault
Main blower fault
Locking; the device locks itself after 2
unsuccessful starts *
)
Undervoltage
Indicating flameout
5 minutes after fault indication
Blink interval
Fault description
Yellow
Red
Overheat
Green
26CC / 40CC
D80151
- 59 -
30 s
2 s
2 s
2 s
2 s
490525C