Classic paraffin 1300
5
490130C
ATTACHEMENT ON DECK
Hole diameter for take
trough hole = 60 mm. Use
the exhaust head base plate
as bore template.
1.
Exhaust head 2460 closes by
pressing down and turning
clockwise, opens by turning anti-
clockwise.
2.
Exhaust head is opened for
mounting by pressing in the pin
(2) with a screw-driver etc.
3.
Gasket
Important that the gasket
surfaces and the take through
hole are carefully sealed with
silicone seal.
A.
The exhaust head is mounted on
deck with bolts (4) (M5 x 90) and
nuts (5) with lock washer (5x)
under. Tight the nuts, but not so
hard the base plate deforms.
B.
Place the spacing tube (6) and
mounting plate (7) on bolts (4)
and fasten with nuts (8) with lock
washers (8x) under. Tight the
nuts, but not so hard the exhaust
base plate deforms.
C.
Check and retighten the nuts (5)
and again the nuts (8).
D.
Place the heater on
mounting plate (7).
The cant (7k) helps to hold
up the heater.
Check that the heater
exhaust pipe goes well in
the exhaust head middle
pipe.
E.
Fasten the heater on mounting
plate (7) with bolts (9) (M8 x
130mm) and tight them.
21.
Check that the heater is
mounted so that the
overheating cut-out reset
button (21) is accessible
for hand.