Classic paraffin 1300
4
490130C
Important!
The fuel lines must be placed so
that the black excess fuel return
tube has continuous fall toward
tank. Loops upward from airlocks,
which hinder the free return of
excess fuel and can cause
burning disturbances and
shooting.
Fuel tanks (mm)
lenght
height
width
2024, 5 L, upright
195
290
125
2027, 10 L, low profile
380
195
210
FUEL LINES
17.
The fuel tank must be placed so
that it always – also under heeling
lies below the heater bottom level.
22.
The tank vent tube end must be
taken so high that fuel from tank
is not spilled out in the vessel
when it heals.
16.
The tank filter must absolutely be
mounted at the end of the fuel
suction tube in the tank to shield
the pump against impurities and
water and to hold the suction tube
down pressed.
25.
The tank connector The black
return tube (11) and transparent
suction tube (21) are taken
through the connector pipes and
secured with rubber
sleeves
(24). The tubes are there after cut
to
suitable length, the suction
tube straight off. The suction filter
(16) is mounted at the suction
tube end with nut (18),
rubber
ring (19) and plastic shield washer
(20).
11.
Excess fuel return tube, Ø 5/3
mm, Polyamid, black 21. Fuel
suction tube, Ø 5/2 mm,
Polyamid,
transparent
22.
Tank vent tube, Ø 7/5 mm, PVC
24.
Rubber sleeves securing the fuel
tubes
25.
Tank connector-take through plate
26.
Tank connector screw collar
holder
23.
Rubber gasket ring
16. Tank filter
18. Filter holder nut
19. Filter holder nut rubber ring
20. Filter shield washer ring
27.
Shield spiral hinders water
intake by holding the suction end
free from tank bottom.
ENGLISH