APPENDIX C : Remote Installations 

 
 
Figure 7 a :  

 

 

 

 

 

 

Figure 7 b : 

 

 

 
 

OTHER REQUIREMENTS :

 

Ground surface water must not flood the unit.  
Avoid condensation / excessive moisture. 
Take adequate precautions against freezing of liquids inside 
the UNI-SAN and in all pipework in and out of the unit. 
 
Easy access for maintenance. Install a union/coupling in the 
delivery pipe close to the motor/pump. 
 
Permanent sturdy support - do not use particle board. 
House to keep dry, away from UV, and human interference. 
Provide drainage in the support in case of overflow  out of the 
unit / leaks in the housing cover. 
 
Vent the tank to appropriate height required by Building & 
Plumbing Code; 

do not use air admittance valve

 
Electrical connection must be earthed and protected by ELCB 

 
IF SHOWER AND/OR BATH CONNECTED

 

Install unshared UNI-SAN Bottom Inlet Valve and waste trap 
for each. 

 
OVERFLOW PROTECTION  :  

Our warranty excludes any damage caused by an overflow. 
Because of the danger of flooding caused by continued 
flushing / discharge in excess of capacity or by a malfunction 
of the pump, particularly as the operation of the quiet motor 
outside the room cannot be heard by the occupants or 
visitors, you should review the safeguards described in 
section 10.4. 
 

Installation on the floor in the same room:

 

An installation inside is simpler. If required, an 
accessible cupboard would effectively hide the 
unit and pipework. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

IF SHOWER AND/OR BATH CONNECTED

 

Install unshared Bottom Inlet Valve for each. 
 
 

OVERFLOW PROTECTION  :  

The risk of flooding is reduced because the 
operation of the unit is audible and warning 
labels are affixed to the fixtures. For peace of 
mind, a pumped appliance should have a 
phase interrupted plug connected and a 
solenoid valve installed on fixtures in other 
rooms. 
 

 
 
 

Continued...

 

Summary of Contents for UNI-SAN

Page 1: ...l view and connections 2 2 Product overview 3 3 Applications 3 4 Features benefits 4 5 Overall building design and Pump hydraulic capability 4 6 Warning for your safety 5 7 List of fittings supplied r...

Page 2: ...k except over the float switch for fixtures or appliances which have an overflow level higher than the unit Allow room for the back nut when cutting the hole Check that either the inflow liquid or the...

Page 3: ...there is one for domestic applications and one for commercial Both units are the same dimensions and pumping performance the major differences are in the materials of construction level control and mo...

Page 4: ...ensions and hydraulic capabilities of the unit Ascertain that the combined inflows into the unit at any time do not exceed 35 litres min Measure the overall height of the delivery pipework from the bo...

Page 5: ...g are coloured in accordance with the following code Earth Green Yellow Neutral Blue Phase Brown 7 LIST OF FITTINGS SUPPLIED AND RECOMMENDED EXTRAS 7 1 Unpacking And Inspection Your UNI SAN package sh...

Page 6: ...The connection to the soil and waste drain system must be carried out in accordance with the Building and Plumbing Code The connection of the unit s delivery pipe to a soil or waste pipe should be kep...

Page 7: ...nk to the valve socket 40 50mm Waste Pipe DRAIN from Floor Waste Gully Trap plumbed as per Appendix C Figure 7c to the valve socket 50 100mm Waste Pipe VENT from WALLACE UNI SAN to approved terminatio...

Page 8: ...BSPF Refer to Section 5 Hydraulic capability to determine the correct pipe size from this connection Slip the delivery pipe in the ends of the swing check valve supplied Check the direction of flow a...

Page 9: ...leaned regularly The unit is not designed as a kitchen waste disposal unit or for the disposal of sewage Refer to our office for the UNI SAN model or other options 10 2 External cleaning The external...

Page 10: ...unit or any other property caused by any un authorised modifications repairs in contravention with the Company s instructions or by use of materials or fittings not supplied by Wallace Pumps Where a c...

Page 11: ...parameters Refer Section 5 Building design If the building or application design is in excess of the pump capability shown on the chart call our office for advice Check that the pump is not pumping th...

Page 12: ...the pump Remove the obstruction Fit 25 mm SWING CHECK VALVE supplied installed in a vertical section of pipe as close as possible within 1 metre of the pump 7 Pump runs and makes a rattling noise Soli...

Page 13: ...otor and pump assembly Do NOT overtighten Check the condition of the o ring Make sure it is not pinched Replace if necessary Check the pressure on the o ring Adjust the 4 nuts as per above Do NOT over...

Page 14: ...ND OR BATH CONNECTED Install unshared UNI SAN Bottom Inlet Valve and waste trap for each OVERFLOW PROTECTION Our warranty excludes any damage caused by an overflow Because of the danger of flooding ca...

Page 15: ...turn non clog full flow ball valve must be installed in a vertical position in the delivery line within a metre of the pump 4 an OVERFLOW PIPE should be installed to maintain the maximum 900mm height...

Reviews: