27-05-19 UNI-SAN Domestic Instructions Page 3 

 

 

The UNI-SAN pump is designed for the disposal of waste water and any solids which can pass through a plumbing 
trap and a waste strainer with a maximum of 10 mm diameter apertures. The unit is capable of pumping the effluent 
from a kitchen waste unit, but it is neither a waste disposal macerator nor suitable for pumping raw sewage waste 
from a toilet. For these other applications, contact Wallace Pumps or a Distributor for other options. 
 
The WALLACE UNI-SAN collects the gravity fed waste liquid into its collection tank. When a set water level is 
reached, the level switch inside the collection tank automatically activates the powerful quiet pump to deliver the 
effluent under pressure to the desired location through a 25 mm internal diameter pipe. The discharge point will 
usually be into a gulley trap or into a soil stack. 
Due to the small pipe size and pump pressure, the delivery can be run virtually anywhere, in any direction, 
 

- through walls, 

 

- through ceiling spaces, 

 

- under floors, 

 

- around, under and over obstacles. 

 
The unit enables the installation of a variety of equipment where this was previously impossible due to economic 
constraints, physical limitations, or because there was no unit available with adequate performance or reliability. 
The UNI-SAN has been developed to overcome these problems, including 
 

- below sewer-line installations, 

 

- where gravity fall is not possible, 

 

- physical restrictions, e.g. concrete walls or concrete floors, 

 

- where new pipes cannot be run under the floor, such as concrete floors, 

 

- where large diameter 80 - 100 mm gravity lines are not appropriate for the location, 

 

- and many other situations. 

 

3.  APPLICATIONS 

The UNI-SAN range is made up of two models, and as the names suggest there is one for domestic applications 
and one for commercial.  Both units are the same dimensions and pumping performance, the major differences are 
in the materials of construction, level control and motor switching design. 
 
The UNI-SAN DOMESTIC is NOT to be used in commercial applications. 
The UNI-SAN collects and automatically pumps away waste water from the following and many other sources : 
 

- laundry tubs, 

 

- domestic and commercial sinks with or without waste disposal units, 

 

- domestic and commercial clothes washing machines, 

 

- domestic and commercial dishwashing machines, 

 

- bar facilities, 

 

- bath, shower, vanity, 

 

- air conditioning condensate, 

 

- dehumidifier water, 

 

- a floor waste gully trap plumbed according to AS3500 and Appendix C, 

Figure 7c

 

PROVIDED THAT  
- in a multi-storey construction, they are all located on the same floor level as the UNI-SAN, 
- maximum temperatures in the collection tank are 60

C continuous and 95

C intermittent, 

- no acids, solvents, paints, petroleum products, corrosive/abrasive liquids or excessive fats are discharged 
into the unit  
- and the volume of water discharged into the unit from fixtures and/or appliances operating at the same 
time must not exceed pump output. 

 
Contact our office for advice : 
- for inflows higher than 35 litres per minute, 
- for general commercial applications, 
- where there is a high quantity of fats being discharged, 
- for printing, photographic or similar trade processing waste. 
Typical applications for the UNI-SAN DOMESTIC are : 
 

- basement facilities  

 

- relocated domestic amenities where gravity fall to existing sewer connections is not possible 

 

- master bedroom en-suites without toilet ( Refer MULTI-SAN unit for toilet applications ) 

 

- executive bars and showers 

 

- re-developed apartment blocks in inner cities enabling waste pipes in ceilings 

 
Typical applications for the UNI-SAN COMMERCIAL are : 
 

- arcade or retail developments including hair salons, cafeterias, delicatessens, etc.

 

 

- amenities in factories built on concrete floor slabs 

Summary of Contents for UNI-SAN

Page 1: ...l view and connections 2 2 Product overview 3 3 Applications 3 4 Features benefits 4 5 Overall building design and Pump hydraulic capability 4 6 Warning for your safety 5 7 List of fittings supplied r...

Page 2: ...k except over the float switch for fixtures or appliances which have an overflow level higher than the unit Allow room for the back nut when cutting the hole Check that either the inflow liquid or the...

Page 3: ...there is one for domestic applications and one for commercial Both units are the same dimensions and pumping performance the major differences are in the materials of construction level control and mo...

Page 4: ...ensions and hydraulic capabilities of the unit Ascertain that the combined inflows into the unit at any time do not exceed 35 litres min Measure the overall height of the delivery pipework from the bo...

Page 5: ...g are coloured in accordance with the following code Earth Green Yellow Neutral Blue Phase Brown 7 LIST OF FITTINGS SUPPLIED AND RECOMMENDED EXTRAS 7 1 Unpacking And Inspection Your UNI SAN package sh...

Page 6: ...The connection to the soil and waste drain system must be carried out in accordance with the Building and Plumbing Code The connection of the unit s delivery pipe to a soil or waste pipe should be kep...

Page 7: ...nk to the valve socket 40 50mm Waste Pipe DRAIN from Floor Waste Gully Trap plumbed as per Appendix C Figure 7c to the valve socket 50 100mm Waste Pipe VENT from WALLACE UNI SAN to approved terminatio...

Page 8: ...BSPF Refer to Section 5 Hydraulic capability to determine the correct pipe size from this connection Slip the delivery pipe in the ends of the swing check valve supplied Check the direction of flow a...

Page 9: ...leaned regularly The unit is not designed as a kitchen waste disposal unit or for the disposal of sewage Refer to our office for the UNI SAN model or other options 10 2 External cleaning The external...

Page 10: ...unit or any other property caused by any un authorised modifications repairs in contravention with the Company s instructions or by use of materials or fittings not supplied by Wallace Pumps Where a c...

Page 11: ...parameters Refer Section 5 Building design If the building or application design is in excess of the pump capability shown on the chart call our office for advice Check that the pump is not pumping th...

Page 12: ...the pump Remove the obstruction Fit 25 mm SWING CHECK VALVE supplied installed in a vertical section of pipe as close as possible within 1 metre of the pump 7 Pump runs and makes a rattling noise Soli...

Page 13: ...otor and pump assembly Do NOT overtighten Check the condition of the o ring Make sure it is not pinched Replace if necessary Check the pressure on the o ring Adjust the 4 nuts as per above Do NOT over...

Page 14: ...ND OR BATH CONNECTED Install unshared UNI SAN Bottom Inlet Valve and waste trap for each OVERFLOW PROTECTION Our warranty excludes any damage caused by an overflow Because of the danger of flooding ca...

Page 15: ...turn non clog full flow ball valve must be installed in a vertical position in the delivery line within a metre of the pump 4 an OVERFLOW PIPE should be installed to maintain the maximum 900mm height...

Reviews: