27-05-19 UNI-SAN Domestic Instructions Page 5 

 

 

 

NB: 

The above chart and figures are based on using Class B or D or 4.5 PVC pressure pipes and one 32 mm 

swing check valve. This will ensure a minimum delivery flow of 35 litres per minute from the WALLACE UNI-SAN. 
This is in excess of the highest output domestic washing machine that is currently known to be available. If you are 
uncertain, call your appliance supplier for the output flow for your particular unit. 
 

6.  WARNING : FOR YOUR SAFETY 

 
The UNI-SAN unit requires a power supply rating of 230 Volts 50 Hz single phase.  
This apparatus must be earthed. To ensure safe operation, check that the three pin power point is earthed and 
protected by a fuse or ELCB protection of an appropriate rating.  
Also check with your local power supply authority. Their requirements may be additional to and over-ride those 
listed above and in section 8.3. 
When opening the cover or inspection lid, always switch the power off and ensure no liquid flows into the tank. 
To prevent shock or fire hazard, do not expose this unit to rain, any type of moisture, flooding or overflows. 
The wires in the main connection plug are coloured in accordance with the following code : 
Earth : Green/Yellow 

 

Neutral : Blue   

Phase : Brown 

 

7.  LIST OF FITTINGS SUPPLIED AND RECOMMENDED EXTRAS 

 
7.1 Unpacking And Inspection 

Your UNI-SAN package should contain the following items 
 

1 x WALLACE UNI-SAN pump unit 

 

1 x 40 mm PVC valve socket, back-nut and washer for a 40 mm inflow waste pipe  

 

1 x 32 mm PVC valve socket, back-nut with washer for the tank vent pipe 

 

1 x 25 mm PVC swing check valve 

 

1 x 25 mm PVC isolating ball valve 

 

1 x 25 mm PVC union 

 

7.2 Options And Supplies :

  

Additional materials you may require from your plumber/installer or local plumbing or building merchant : 

40 mm UNI-SAN Bottom Inlet Valve for connecting a shower tray or a bath 
PVC valve sockets with back-nuts and washers to suit the appropriate pipework 
32mm - 50 mm PVC drain waste pipe(s) into the UNI-SAN 
32 mm PVC waste pipe and cowl for the vent from the collection tank 
25 mm (refer Figure 5) Class B or D or 4.5 PVC pressure pipe for the delivery pipe 
any other size pipes as required 
PVC fittings and cement as required (bends, sockets, traps and waste strainers, etc. ) 
PVC pipe "lubricant" (do not use petroleum based products) 
Thread tape - do not use hemp. 
Silicone sealant.  

 
 

 
7.3 Tools Required for the installation

   

Stanley knife, or jig saw or hacksaw (for cutting out delivery pipe slot in the cover ) 

 

Half round file 

Summary of Contents for UNI-SAN

Page 1: ...l view and connections 2 2 Product overview 3 3 Applications 3 4 Features benefits 4 5 Overall building design and Pump hydraulic capability 4 6 Warning for your safety 5 7 List of fittings supplied r...

Page 2: ...k except over the float switch for fixtures or appliances which have an overflow level higher than the unit Allow room for the back nut when cutting the hole Check that either the inflow liquid or the...

Page 3: ...there is one for domestic applications and one for commercial Both units are the same dimensions and pumping performance the major differences are in the materials of construction level control and mo...

Page 4: ...ensions and hydraulic capabilities of the unit Ascertain that the combined inflows into the unit at any time do not exceed 35 litres min Measure the overall height of the delivery pipework from the bo...

Page 5: ...g are coloured in accordance with the following code Earth Green Yellow Neutral Blue Phase Brown 7 LIST OF FITTINGS SUPPLIED AND RECOMMENDED EXTRAS 7 1 Unpacking And Inspection Your UNI SAN package sh...

Page 6: ...The connection to the soil and waste drain system must be carried out in accordance with the Building and Plumbing Code The connection of the unit s delivery pipe to a soil or waste pipe should be kep...

Page 7: ...nk to the valve socket 40 50mm Waste Pipe DRAIN from Floor Waste Gully Trap plumbed as per Appendix C Figure 7c to the valve socket 50 100mm Waste Pipe VENT from WALLACE UNI SAN to approved terminatio...

Page 8: ...BSPF Refer to Section 5 Hydraulic capability to determine the correct pipe size from this connection Slip the delivery pipe in the ends of the swing check valve supplied Check the direction of flow a...

Page 9: ...leaned regularly The unit is not designed as a kitchen waste disposal unit or for the disposal of sewage Refer to our office for the UNI SAN model or other options 10 2 External cleaning The external...

Page 10: ...unit or any other property caused by any un authorised modifications repairs in contravention with the Company s instructions or by use of materials or fittings not supplied by Wallace Pumps Where a c...

Page 11: ...parameters Refer Section 5 Building design If the building or application design is in excess of the pump capability shown on the chart call our office for advice Check that the pump is not pumping th...

Page 12: ...the pump Remove the obstruction Fit 25 mm SWING CHECK VALVE supplied installed in a vertical section of pipe as close as possible within 1 metre of the pump 7 Pump runs and makes a rattling noise Soli...

Page 13: ...otor and pump assembly Do NOT overtighten Check the condition of the o ring Make sure it is not pinched Replace if necessary Check the pressure on the o ring Adjust the 4 nuts as per above Do NOT over...

Page 14: ...ND OR BATH CONNECTED Install unshared UNI SAN Bottom Inlet Valve and waste trap for each OVERFLOW PROTECTION Our warranty excludes any damage caused by an overflow Because of the danger of flooding ca...

Page 15: ...turn non clog full flow ball valve must be installed in a vertical position in the delivery line within a metre of the pump 4 an OVERFLOW PIPE should be installed to maintain the maximum 900mm height...