27-05-19 UNI-SAN Domestic Instructions Page 2 

 

 

Figure 3 : Connections and names of parts 

 

 

1.  

Cover 

for pump, motor and controls. Lift to remove. 

2. 

Inspection lid 

- Screw in type with o-ring seal; turn anti-clockwise to remove. The unit must be installed upright 

with the inspection lid on top. 

3. 

Collection tank

 - Fittings supplied are shipped inside. Cut holes neatly and carefully. Do not subject to impacts, 

scratches, scouring or partial drilling that may weaken it. Take care not to damage internal parts with hole saws. 
If the unit is not installed in the same room as the fixtures, it should be plumbed according to Appendix C. Access 
must be provided for maintenance at all times. 

4. 

Pump delivery

 25 mm BSPF -3 optional directions. Use Class B or D or Class 4.5 PVC pressure pipe. Install a 

union/coupling close to the pump for future pump removal without disturbing the pipework. Securely strap and 
isolate the pipe from the building structure to prevent vibration or noise transmission during operation. Any 
horizontal section of the delivery pipework should always have a continuous rise towards the soil or waste pipe 
connection. It should never be level or have a fall. 

5. 

Tank vent connection

 - 32 mm valve socket is supplied inside the tank. Use 32 mm pipe to run the vent to a 

termination point in accordance with the Building and Plumbing Code. 

Do not use an air admittance valve

e.g. a "Hunter Valve".

  

6. 

Inlet connections

 using PVC valve sockets with back-nuts and washers can be installed anywhere on the four 

walls, or the top of the collection tank (except over the float switch) for fixtures or appliances which have an 
overflow level higher than the unit. Allow room for the back-nut when cutting the hole. Check that either the inflow 
liquid or the protruding pipe inside the tank will not damage fittings inside the tank or hinder the operation of the 
float level switch. One 40 mm valve socket is supplied with the unit. 

7. 

UNI-SAN Bottom Inlet Valve

, unless the unit is installed below the floor level, should be used for a shower or 

a bath connection, not shared with any other connecting fixtures or appliances. If both are connected, each must 
have its own UNI-SAN Bottom Inlet Valve. It can be made with a hole-saw on any of the four walls, 80mm centre 
height from the base. The inlet pipe must be braced to prevent the water pressure from dislocating the push-fit 
connection. 

The valve is purchased separately

8.  All fixtures and appliances connecting into the UNI-SAN must discharge through 

a trap and a waste strainer

 

with a maximum of 10mm diameter apertures. All pumped appliances, such as washing machines and 
dishwashers, must discharge via an approved waste system which includes an air gap and a trap. 

9. The 25 

mm swing check valve

 supplied must be installed in the delivery pipe in a vertical position within one 

metre (pipe length) of the unit to stop backflow of liquid from the pipe back into the collection tank. The 25 mm 
union shouldbe installed between the pump and this valve. 

10. 

Isolation Valve

 – A 25

 mm full flow ball valve

 for installation after the 25 mm swing check valve is supplied 

11. 

Labels

 warning against inappropriate discharges are supplied and should be affixed on the appropriate fixtures 

and appliances connected. 

 
 
 

2.  PRODUCT OVERVIEW 

 

9. 25 mm swing 
check valve 

Summary of Contents for UNI-SAN

Page 1: ...l view and connections 2 2 Product overview 3 3 Applications 3 4 Features benefits 4 5 Overall building design and Pump hydraulic capability 4 6 Warning for your safety 5 7 List of fittings supplied r...

Page 2: ...k except over the float switch for fixtures or appliances which have an overflow level higher than the unit Allow room for the back nut when cutting the hole Check that either the inflow liquid or the...

Page 3: ...there is one for domestic applications and one for commercial Both units are the same dimensions and pumping performance the major differences are in the materials of construction level control and mo...

Page 4: ...ensions and hydraulic capabilities of the unit Ascertain that the combined inflows into the unit at any time do not exceed 35 litres min Measure the overall height of the delivery pipework from the bo...

Page 5: ...g are coloured in accordance with the following code Earth Green Yellow Neutral Blue Phase Brown 7 LIST OF FITTINGS SUPPLIED AND RECOMMENDED EXTRAS 7 1 Unpacking And Inspection Your UNI SAN package sh...

Page 6: ...The connection to the soil and waste drain system must be carried out in accordance with the Building and Plumbing Code The connection of the unit s delivery pipe to a soil or waste pipe should be kep...

Page 7: ...nk to the valve socket 40 50mm Waste Pipe DRAIN from Floor Waste Gully Trap plumbed as per Appendix C Figure 7c to the valve socket 50 100mm Waste Pipe VENT from WALLACE UNI SAN to approved terminatio...

Page 8: ...BSPF Refer to Section 5 Hydraulic capability to determine the correct pipe size from this connection Slip the delivery pipe in the ends of the swing check valve supplied Check the direction of flow a...

Page 9: ...leaned regularly The unit is not designed as a kitchen waste disposal unit or for the disposal of sewage Refer to our office for the UNI SAN model or other options 10 2 External cleaning The external...

Page 10: ...unit or any other property caused by any un authorised modifications repairs in contravention with the Company s instructions or by use of materials or fittings not supplied by Wallace Pumps Where a c...

Page 11: ...parameters Refer Section 5 Building design If the building or application design is in excess of the pump capability shown on the chart call our office for advice Check that the pump is not pumping th...

Page 12: ...the pump Remove the obstruction Fit 25 mm SWING CHECK VALVE supplied installed in a vertical section of pipe as close as possible within 1 metre of the pump 7 Pump runs and makes a rattling noise Soli...

Page 13: ...otor and pump assembly Do NOT overtighten Check the condition of the o ring Make sure it is not pinched Replace if necessary Check the pressure on the o ring Adjust the 4 nuts as per above Do NOT over...

Page 14: ...ND OR BATH CONNECTED Install unshared UNI SAN Bottom Inlet Valve and waste trap for each OVERFLOW PROTECTION Our warranty excludes any damage caused by an overflow Because of the danger of flooding ca...

Page 15: ...turn non clog full flow ball valve must be installed in a vertical position in the delivery line within a metre of the pump 4 an OVERFLOW PIPE should be installed to maintain the maximum 900mm height...

Reviews: