3
Specifications
Model Numbers Covered in this Specification
RN[1]8110GE
Gas Target Top Range Electric Static Oven - 900mm.
RN[1]8110GEC
Gas Target Top Range Electric Convection Oven - 900mm.
NOTE:
[1]: - Back Options;
-
- Standard Models.
L
- Low Back Models.
General
A commercial heavy duty, gas fired Target Top having a high output, two stage double-ring cast iron
burner offering accurate temperature control and infinitely variable heat with heat radiating out from
centre of Target Top. The Main Burner is located underneath removable cast target top plates.
With a heavy duty, high efficiency electric static or convection oven options, fitted with a 900mm,
6.5kW electric static oven and a 6.6kW Convection Oven created for compact modular kitchens.
Both ovens are fitted with 4.5 kW bottom element and 2.0kW top element. The Convection oven is
fitted with a 100W oven fan motor.
Gas Supply Requirements
NOTE:
(**) Measure burner operating pressure at target top hob manifold test point with target
top burner (Inner and outer ring) operating at full setting.
NAT, LPG & Butane Only - Operating pressure is ex-factory set and is not to be
adjusted, apart from when converting between gasses, if required.
TOWN GAS Only - Burner operating pressure is to be adjusted using adjustable gas
regulator supplied. Town Gas Option is only available with specific ex-factory built
Town Gas models, which can also be converted to any other gas. Standard models can
only be converted between Nat. Gas, LP Gas and Butane, but not Town Gas.
Refer to ‘Gas Conversion and Specifications' section of this manual for further
details.
Gas Connection
Gas supply connection point is located at rear of appliance, approximately 130mm from right hand
side, 32mm from rear, 655mm from floor and is reached from beneath appliance. An optional
underside connection is available. (Refer to ‘Dimensions’ section).
Connection is ¾" BSP male thread.
Natural Gas
LP Gas / Butane
Input Rating
45 MJ/hr
45 MJ/hr
(N.H.G.C.)
(42,650 BTU)
42,650 BTU)
Supply Pressure
1.13 - 3.40 kPa
2.75 - 4.50 kPa
(4.5” - 13.5” w.c.)
(11” - 18” w.c.)
Operating Pressure
1.0 kPa (*)
2.6 kPa (*)
(4.0” w.c.)
(10.0” w.c.)
Gas Connection
¾” BSP Male
Town Gas (**)
45 MJ/hr
42,650 BTU)
0.75 - 1.50 kPa
(3” - 6” w.c.)
0.63 kPa (*)
(2.5” w.c.)