Waldorf RN8110GE Installation And Operation Manual Download Page 25

23 

Replacement Parts List 

Replacement Parts List 

When ordering replacement parts, please quote part number and description as listed below.  If part 

required is not listed, request part by description and quote model number and serial number as shown on 

rating plate. 

 

 

Target Top 

228853 Burner. 

230511 Pilot 

Burner 

Kit. 

235347 Thermocouple 

Kit. 

017800 

Gas Control Valve 

(Nat / LPG / Butane). 

227384 

Gas Control Knob 

(Nat / LPG / Butane). 

229699 

Gas Control Valve 

(Town Gas). 

229693 

Gas Control Knob 

(Town Gas). 

031170 

Injector Inner Ring  

(Nat)  

Ø 1.70 mm. 

031110 

Injector Inner Ring  

(LPG)  

Ø 1.10 mm. 

031100 

Injector Inner Ring  

(Butane) 

Ø 1.00 mm. 

031420 

Injector Inner Ring  

(Town Gas) 

Ø 4.20 mm. 

031260 

Injector Outer Ring  

(Nat)  

Ø 2.60 mm. 

031155 

Injector Outer Ring  

(LPG)  

Ø 1.55 mm. 

031145 

Injector Outer Ring  

(Butane)  

Ø 1.45 mm. 

031630 

Injector Outer Ring  

(Town Gas)  

Ø 6.30 mm. 

227985 

Pilot Injector  

(Nat)  

0.35. 

227984 

Pilot Injector  

(LPG / Butane)  

0.25. 

232310 

Pilot Injector  

(Town Gas)  

0.70. 

 

 

Oven 

228691  

Oven Top Element 1.75 kW.   

(750 Ovens). 

228690  

Oven Bottom Element 3.75 kW. 

(750 Ovens). 

228082 

Oven Top Element 2 kW. 

  

(900 - 1200 Ovens). 

228059 

Oven Bottom Element 4.5 kW. 

(900 - 1200 Ovens). 

228704 Door 

Spring 

Kit. 

229021 Terminal 

Block 

Mains. 

227399 

Control Knob Thermostat 50°C - 300°C. 

229146 

Thermostat 50 - 300°C. 

229145 Switch 

(4-pole). 

013989 Energy 

Regulator. 

227398 

Control Knob  HI / LO Heat. 

 

Convection Oven Only 

228938 Oven 

Door 

Microswitch. 

010909 Motor 

Capacitor 

4µf. 

228116 Fan. 

019479 Motor. 

IMPORTANT: 

 

Only genuine authorized replacement parts should be used for servicing and  
repair of this appliance.  Instructions supplied with parts should be followed 
when replacing components. 
 
For further information and servicing instructions, contact your nearest 

 

authorized service branch (contact details are as shown on reverse of front 
cover of this manual). 

Summary of Contents for RN8110GE

Page 1: ...I n s t a l l a t i o n a n d O p e r a t i o n M a n u a l Gas Target Top Range Electric Ovens Date Purchased Serial Number Dealer Service Provider 232456 10 RN8110GE RN8110GEC RNL8110GE RNL8110GEC...

Page 2: ...337 963 Customer Service tel 1800 335 315 fax 1800 350 281 CANADA Serve Canada Web www servecanada com E Mail info servecanada com Sales tel 800 551 8795 Toll Free Service tel 800 263 1455 Toll Free...

Page 3: ...sions 5 Installation 6 Installation Requirements Unpacking Location Clearances Assembly Rear Rollers Fitting Gas Connection Electrical Connection Commissioning Operation 11 Operation Guide Description...

Page 4: ...RECT AND SAFE OPERATION OF YOUR APPLIANCE IS MAINTAINED DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPOURS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE DO NOT SPRAY AEROSOLS IN THE V...

Page 5: ...urner Inner and outer ring operating at full setting NAT LPG Butane Only Operating pressure is ex factory set and is not to be adjusted apart from when converting between gasses if required TOWN GAS O...

Page 6: ...S NZS 3191 part 2 10 11 or IEC 60245 IEC 57 e g HO5 RN F Type The branch supply line shall be individually overload protected to the correct current rating and the supply chord shall be protected agai...

Page 7: ...5 Dimensions Dimensions RN L 8110GE GEC...

Page 8: ...g all protective plastic coating from exterior stainless steel panels Check equipment and parts for damage Report any damage immediately to carrier and distributor Report any deficiencies to distribut...

Page 9: ...ng instructions Optional Accessories Refer to the Replacement Parts List Plinth Kit For installation details refer to instructions supplied with each kit Fitting Rear Rollers 1 Raise appliance from fl...

Page 10: ...re at target top hob manifold test point with target top burner Inner and outer ring operating at full setting NAT LPG Butane Only Operating pressure is ex factory set and is not to be adjusted apart...

Page 11: ...nection terminals Refer to Electrical Supply Requirements section for connection details NOTE This appliance can be converted from 3 Phase to Single Phase supply by connecting single phase input to L1...

Page 12: ...draw and loading for the equipment Refer specification section for correct electrical requirements Check that all the connections are correct and that all cover panels have been re fitted Ensure that...

Page 13: ...Heating Indicator Lamps Amber for Top Bottom Elements Power Indicator Lamp green Target Top Gas Control Knob OFF Position PILOT Burner HIGH Flame LOW Flame Oven Top Heat Control OFF Position LOW Posit...

Page 14: ...be burning at full rate For a lower heat turn gas control knob fully anti clockwise to LOW position 5 Also for intermediate heat position gas control knob between HIGH and LOW positions NOTE Always se...

Page 15: ...op heat control to desired setting NOTE When oven top heat control is set to a high setting proportionally more heat is produced at top of oven This can be used for browning etc during cooking operati...

Page 16: ...h back interior and exterior surfaces of Target Top Range with hot water a mild detergent solution and a soft scrubbing brush 2 Clean control panel with a damp cloth lightly moistened with a solution...

Page 17: ...e an approved stainless steel cleaner or stainless steel wool Always rub in direction of grain d Dry all components thoroughly with a dry cloth and polish with a soft dry cloth Periodic Maintenance NO...

Page 18: ...ion valve is turned On and bottles are not empty Call service provider Pilot goes out when gas control knob released Releasing knob before thermocouple has heated Pilot flame too small Gas pressure to...

Page 19: ...17 Wiring Schematic RN L 8110GE...

Page 20: ...18 Wiring Schematic RN L 8110GEC...

Page 21: ...19 Wiring Schematic Wiring Layout for Static Oven Wiring Layout for Convection Oven...

Page 22: ...ctors and replace with correct size injectors as shown in Gas Specifications Tables at rear of this section 3 Refit main burner to target top NOTE Ensure main burner is pulled fully towards front of u...

Page 23: ...with coloured paint on completion of low fire adjustment Gas Regulator NAT Gas LPG Butane Only NOTE Gas regulator supplied is convertible between Natural Gas and LP Gas but it s outlet pressure is fix...

Page 24: ...re burner operating pressure at target top hob manifold test point with target top burner Inner and outer ring operating at full setting NAT LPG Butane Only Operating pressure is ex factory set and is...

Page 25: ...ector Outer Ring Town Gas 6 30 mm 227985 Pilot Injector Nat 0 35 227984 Pilot Injector LPG Butane 0 25 232310 Pilot Injector Town Gas 0 70 Oven 228691 Oven Top Element 1 75 kW 750 Ovens 228690 Oven Bo...

Page 26: ...sion Kits Australia New Zealand Only NOTE Town Gas Option is only available with specific ex factory built Town Gas models which can also be converted to any other gas Standard models can only be conv...

Page 27: ......