245.805.011
9
Date: 2021-12-09
Safety functions
The control system ensures that the motor only is powered when:
The DMX signal is reliable.
The mode, position and speed control are set correctly.
The drum position is within the span of the soft and hard limits.
No overload.
Winch 50 Series should only be operated by an experienced DMX-controlled-lighting-desk-
operator. The lighting desk must be programmed according to the manual, so the winch will stop
when the speed is put to 0 %. It is also possible for the user to stop the winches by disconnecting
it from the mains. After power failure the start position of the winch may need to be adjusted
before the winch can function properly again.
Manual operation of the winch is only intended for installation, service, and tests.
Area of use
WARNING! To reduce the risk of electric shock or injury use indoors only.
WARNING! To reduce the risk of electric shock, do not expose to rain.
The Winch 50 Series is intended for indoor use only. It is designed for lifting and lowering material
at the weight and speed stated in "Technical specifications" on page 4. Any other use of the
product may result in a risk of injury of persons or equipment damage.
Exceeding the load rating may cause failure of the equipment.
Use only the Wahlberg Motion Design approved mounting connectors to secure the load to the
winch. Failure to mount the load securely can result in a risk of injury of persons or equipment
damage.
Do not modify the product. For any modification contact Wahlberg Motion Design.
It is the customer's sole responsibility to comply with any relevant local laws, regulatory
requirements, and restrictions, concerning the use of the product.
Using for the first time
IMPORTANT! The Winch 50 Series must be protected from environmental factors such as
physical shocks and vibration during transportation and storage.
WARNING
2 before installing, powering, operating, or
servicing the Winch 50 Series. Before applying power to the product.
Check the Wahlberg Motion Design website at
www.wahlberg.dk
for the most recent
documentation and technical information about the product. Wahlberg Motion Design user
manual revisions are identified by the revision number in the bottom of each page.
2.
Check that the local AC mains power source is within the power voltage and frequency ranges.
page 13. Install the provided Neutrik powerCON TRUE1
NAC3FX-W-TOP power connector on a suitable power cable. If using the power from a mains
power outlet, install a suitable power plug on the power cable.
Summary of Contents for 50 Series
Page 37: ...245 805 011 37 Date 2021 12 09 Winch 50 245...
Page 38: ...245 805 011 38 Date 2021 12 09 Winch 50 Double 246 701...
Page 39: ...245 805 011 39 Date 2021 12 09 Winch 50 Double Power and Cat5 246 704...
Page 40: ...245 805 011 40 Date 2021 12 09...
Page 41: ...245 805 011 41 Date 2021 12 09...
Page 43: ...245 805 011 43 Date 2021 12 09 This page is intentionally left blank...