Analog Inputs 750-467,468,487,488
:$*2
Ç
,
2
Ç
6<67(0
4
The numerical format for Siemens
In addition to the full 16 bit indication of the measured value it is possible to use the
‘Siemens format’. The measured value is represented by the most significant 12 Bits.
The 3 least significant Bits are reserved for diagnostic and status purposes. (750-487,
488)
Input
voltage
0-10V
Binary value
X : without
meaning
F : short circuit or
F : open circuit
Ü : overflow
X F Ü
Hex.
Dec.
Status
>10
0101 0000 0000 0
0 0 1
50 01
20481
42
10
0101 0000 0000 0
0 0 0
50 00
20480
0
5
0011 0000 0000 0
0 0 0
30 00
12288
0
2,5
0010 0000 0000 0
0 0 0
20 00
8192
0
1,25
0001 1000 0000 0
0 0 0
18 00
6144
0
0,0049
0001 0000 0000 1
0 0 0
10 08
4104
0
0
0001 0000 0000 0
0 0 0
10 00
4096
0
If you have questions about the formatting of this data, please contact WAGO for