80 Appendix
852-1322/852-1328 Industrial Managed Switch
Manual
1.0.01
Table 37: Modbus-Register
Address
Data Type
Read/Write Description
Port Status
0x1000
(4096)
5 words
R
Port Status
0x0000: Disabled
0x0001: Enabled
Word 0 Hi byte = Port 1 Status
Word 0 Lo byte = Port 2 Status
Word 1 Hi byte = Port 3 Status
Word 1 Lo byte = Port 4 Status
Word 2 Hi byte = Port 5 Status
Word 2 Lo byte = Port 6 Status
Word 3 Hi byte = Port 7 Status
Word 3 Lo byte = Port 8 Status
Word 4 Hi byte = Port 9 Status
Word 4 Lo byte = Port 10 Status
0x1040
(4160)
5 words
R
Port Speed
Status, 10M = 0x01
Status, 100M = 0x02
Status, 1000M = 0x03
Word 0 Hi byte = Port 1 Status
Word 0 Lo byte = Port 2 Status
Word 1 Hi byte = Port 3 Status
Word 1 Lo byte = Port 4 Status
Word 2 Hi byte = Port 5 Status
Word 2 Lo byte = Port 6 Status
Word 3 Hi byte = Port 7 Status
Word 3 Lo byte = Port 8 Status
Word 4 Hi byte = Port 9 Status
Word 4 Lo byte = Port 10 Status
0x10A0
(4256)
5 words
R
Port Link Status
Status, down = 0x00
Status, up = 0x01
Word 0 Hi byte = Port 1 Status
Word 0 Lo byte = Port 2 Status
Word 1 Hi byte = Port 3 Status
Word 1 Lo byte = Port 4 Status
Word 2 Hi byte = Port 5 Status
Word 2 Lo byte = Port 6 Status
Word 3 Hi byte = Port 7 Status
Word 3 Lo byte = Port 8 Status
Word 4 Hi byte = Port 9 Status
Word 4 Lo byte = Port 10 Status
31.8