62 Configuration in the WBM
852-1322/852-1328 Industrial Managed Switch
Manual
1.0.01
Table 29: WBM “Diagnostics” Page – “System Log” – “Setting” Tab
Parameters
Factory Default Description
Enable Log
Event to Flash
Uncheck
Checked:
Saving log event into flash memory. The flash
memory can keep the log event files even if the switch is
rebooted.
Unchecked
: Saving log event into RAM memory. The RAM
memory cannot keep the log event files after each reboot.
Log Level
3(:LOG_ERR)
Set the log level to determine what events to be displayed on
the next webpage (Log). The level selection is inclusive. For
example, if 3 (:Log_ERR) is selected, all 0, 1, 2 and 3 log
levels will be implied.
Range from Log 0 to Log 7.
Enable Syslog
Server
Uncheck
Checked
: Enable Syslog Server.
Uncheck
: Disable Syslog Server.
If enabled, all recorded log events will be sent to the remote
System Log server.
Syslog Server
IP
0.0.0.0
Set the IP address of Syslog server
Syslog Server
Service Port
514
Set the service port number of Syslog server.
Range from Port 1 to Port 65535.
7.5.3.2 Log
The Log tab page under the System Log as shown in Figure “System Log Page”
can display the log information based on the log level configured in the System
Log Setting tab page (previous subsection). The user has options to either Read
all notifications or Read only the last
n
records of the log. This can be selected by
clicking on the corresponding radio button.
Figure 37: System Log Page
To refresh the display or to enable cyclic refresh, click the
[Refresh]
button. This
[Refresh]
button is only visible if the Automatic refresh cycle option is not
enabled or stopped. To enable cyclic refresh, click the
[Start]
button. The
[Start]
button is only visible if Automatic refresh cycle option is enabled and has not yet
started as shown in Figure “
[Start]
Button is visible when Automatic refresh cycle
is enabled”. To stop cyclic refresh again, click the
[Stop]
button. The
[Stop]