WAGO-I/O-SYSTEM 757
Commissioning
53
757-801 Bluetooth® Module RS-232
Manual
1.0.0
Figure 18: Operating mode status diagram
Table 33: Legend for status diagram
[ ]
Description
[I],[II], [III], [IV]
Start in operating mode …
[W]
Wait for interruption of power supply within a time frame of
3 … 10 s
[?]
Switching of operating mode initiated?
(1)
(0)
Yes
No
[R]
Restore factory default setting
[A]
“AutoConnect” attempts to locate a device of the same type.
When successful: Saving of the modified configuration and
switching to [N]ormal operation.
[N]
Normal operation as defined in the configuration.
- - - - - - - - -
>
Power supply interruption outside the time frame:
Restart in operating mode [I]