30
Function Description
WAGO-I/O-SYSTEM 757
757-801 Bluetooth® Module RS-232
Manual
1.0.0
Table 15: AT Command groups: Section overview
Contents
See section
Check the link to the WAGO radio adapter
“AT”
Call up syntax information
“AT HELP”
Call up device information (status text)
“AT INFO”
Close the AT command interface
“AT LOGOUT”
Restart the WAGO radio adapter
“AT RESET”
Configuration of the device name, the device
address and the CoD
“Group AT BTID”
Security settings
“Group AT BTSEC”
Configuration of outbound links
“Group AT CON”
Coexistence settings
“Group AT ECO”
Search for SPP devices within range
“Group AT INQ”
Query information from SPP devices within range
“Group AT RDEV”
Version and status information
“Group AT STATUS”
AT interface configuration, output format, factory
default settings
“Group AT SYS”
Configuration of the serial interface
“Group AT UART”
Pos : 49.9 /Serie 757 (Funkadapt er I P67)/F unktions beschr eibung/ Funkti onsbesc hrei bung 757-801: Wer ksei nst ellung @ 16\ mod_1374667336835_21.doc x @ 126908 @ 2 @ 1
4.3
Factory Default Settings
On delivery, the device configuration is preset with the following values:
Table 16: Factory settings
Parameter
Default value
Bluetooth
®
device name
WAGO 757-801 SN123456
(example of a device with serial
number 123456)
Bluetooth
®
Class of Device (CoD)
0x1f00
List of allowed devices
(empty)
Enforce secure authentication
OFF
Response to device discovery
when there is no link to the SPP
service “DATA”
Response to paging
always
PIN for inbound connections to external
devices of older
Bluetooth
®
standards
1234
PIN for outbound connections to external
devices of older
Bluetooth
®
standards
1234
Automatic restore of the outbound wireless
connection after restart or loss of connection
OFF
Interval between attempting to
restore/establish the outbound wireless
connection
30 s
Bluetooth
®
address to which an outbound
connection is established
00:00:00:00:00:00 (blank)