WAGO-I/O-SYSTEM 757
Connect Devices
43
757-801 Bluetooth® Module RS-232
Manual
1.0.0
6.3.2
Using the WAGO Interface Module 289-384
You can use the WAGO 289-384 interface module to connect the WSA with
electrical isolation to the service interface of fieldbus couplers or PLCs of the
WAGO-I/O SYSTEM 750.
Figure 16: WAGO 289-384 interface module
Table 22: Connection to the WAGO 289-384 interface module
WAGO 289-384 Interface Module
Direction Connecting Cable 757-801
Terminals
Pin
Marking
Wire Color
Description
WH
RX(out)
White
RX(out)
GY
TX(in)
Gray
TX(in)
BU
GND
-
Blue
GND
BN
24 V
-
Brown
24 V
Shield clamping saddle
-
Shield (screen)
Power supply for the WSA is fed in via the second terminal block.
Table 23: Connection to the WAGO 289-384 interface module, power supply
Power Supply
WAGO 289-384 Interface Module
Terminals
Description
Marking
24 V
24 V
0 V
GND