750-632 Proportional Valve Module
Manual
Version 1.3.0, valid from FW/HW-Version 01/01
6.4
Representation of Target and Actual Values
Table 50: Representation of Target and Actual Values
Short Description Setpoint Value
Actual Value
Target value
V1_TARGET,
V2_TARGET
V1_ACTUAL,
V1_ACTUAL
Data type
INT16
(twos complement)
INT16
(twos complement)
Value range *
-100% … +100%
(-10000 … +10000)
-2000 mA … +2000 mA
(-20000 … +20000)
Resolution
1 LSB corresponds to
0.01%
1 LSB corresponds to 0.1 mA
* See table “number representation” in the appendix
Maintain factory settings!
The following default settings apply to the target value:
-100% ... +100% corresponds to the parameterized nominal current