background image

14

W 600 Flexio 18V

EN

• 

When working with the W 600 indoors as well as outdoors ensure that no solvent 

vapors are sucked in by the spray gun.

• 

The spray gun is not a toy; children must therefore not be allowed to handle it or play 

with it.

• 

Remove the battery before carrying out any work on the spray gun.

• 

Cover areas that are 

not

 to be sprayed. When working keep in mind that wind, for 

example, may transport paint mist over great distances and cause damage.

• 

Never open the device yourself in order to carry out repairs in the electrical system!

• 

The units may only be used with a functional valve. 

If paints rises in the ventilating 

hose (Fig. 1, item 16) do not operate the unit further! 

Dismantle and clean the 

ventilating hose, valve and diaphragm and replace the diaphragm if necessary.

• 

Do not lay the spray gun.

With original WAGNER accessories and spare parts, you have the guarantee that 

all safety regulations are fulfilled. 

4. Safety instructions for the charger and battery

Only use the tool with BOSCH POWER FOR ALL compatible PBA 18V 

batteries with at least 2.5 Ah and suitable chargers. The battery voltage 

must match the battery charging voltage of the charger. Do not charge 

non-rechargeable batteries. Otherwise there is a risk of fire and explosion.

• 

Only use the charger indoors and keep it away from moisture. 

 Water penetrating 

into a power tool increases the risk of an electric shock.

• 

Keep the charger clean.

 There is a risk of electric shock due to contamination.

• 

Before every use, check the charger, cable and plug. Do not use the charger if it is 

damaged. Do not open the charger yourself and only have it repaired by qualified 

specialist personnel using original spare parts. 

Damaged chargers, cables and plugs 

increase the risk of electric shock.

• 

Do not operate the charger on easily combustible surfaces (e.g. paper, textiles, 

etc.) or in combustible environments. 

There is a risk of fire due to the heating of the 

charger during charging.

• 

The battery is delivered partially charged. 

To ensure full battery performance, fully 

charge the battery in the charger before first use.

• 

Only use the battery in the manufacturer's products.

 This is the only way to protect 

the battery from dangerous overloading. 

• 

Keep batteries out of the reach of children.

• 

Do not open the battery. There is a risk of a short circuit.

• 

Vapours may also escape if the battery is damaged or used improperly. 

Take in 

fresh air and consult a doctor if you have any symptoms. The vapours may irritate the 

respiratory tract.

• 

If the battery is defective, liquid may leak out and wet adjacent objects. 

Check 

affected parts. Clean them or replace them if necessary.

• 

The battery can be damaged by sharp objects such as nails or screwdrivers or by 

external force. 

An internal short circuit may occur and the battery may burn, smoke, 

explode or overheat.

Summary of Contents for W 600 FLEXIO 18V

Page 1: ...wagner group com UNIVERSAL SPRAYER W 600 FLEXIO 18V TRANSLATION OFTHE ORIGINAL OPERATING INSTRUCTIONS EN...

Page 2: ...W 600 Flexio 18V b A B a 11 15 16 6 9 4 5 3 1 12 14 18 17 19 7 OVERVIEW 20 8 2 10 13 21 20...

Page 3: ...W 600 Flexio 18V click c a b 1 2 1 I ON 0 OFF...

Page 4: ...W 600 Flexio 18V 2 1 A B C 1 A B 1 2...

Page 5: ...W 600 Flexio 18V 5 15 cm 20 30 cm A B C 1 1 2 3 1 2 3...

Page 6: ...W 600 Flexio 18V 4 2 1 2 2 1 2 3...

Page 7: ...W 600 Flexio 18V 1 2 3 4 5 6 7 1 2 7 8 3 4 5 6 9 1 2 3 3...

Page 8: ...Please read the Operating Manual carefully and observe the safety information before starting the device Store the Operating Manual in a safe place close to the product in case it needs to be used by...

Page 9: ...Wall Extra I Spray spray attachment 19 14 Adjusting the Material Volume Standard spray attachment 19 15 Setting the Amount of Air Fig 11 19 16 Spray Technique 20 17 Interruption of Work 20 18 Taking...

Page 10: ...presence of flammable liquids gases or dust Power tools create sparks which may ignite the dust or fumes c Keep children and bystanders away while operating a power tool Distractions can cause you to...

Page 11: ...witch or energising power tools that have the switch on invites accidents d Removeanyadjustingkeyorwrenchbeforeturningthepowertoolon Awrench or a key left attached to a rotating part of the power tool...

Page 12: ...power tool for operations different from those intended could result in a hazardous situation h Keep handles and grasping surfaces dry clean and free from oil and grease Slippery handles and grasping...

Page 13: ...ar protection and gloves CAUTION DANGER OF INJURY Never point the spray stream towards human beings or animals Sockets and plugs must be masked Risk of an electric shock as a consequence of sprayed ma...

Page 14: ...re Waterpenetrating into a power tool increases the risk of an electric shock Keep the charger clean There is a risk of electric shock due to contamination Before every use check the charger cable and...

Page 15: ...material is required Dispatch battery packs only when the housing is undamaged Tape or mask off open contacts and pack up the battery in such a manner that it cannot move around in the packaging Plea...

Page 16: ...ed material entering the socket Mask all the areas and objects that are not to be spray painted or remove them from the work area No liability is assumed for damage due to overspray Silicate paint cor...

Page 17: ...intsintheirundiluted form If the surface is smooth and the paint you are using is very thick and gel like dilute it by 10 Dilution can be necessary if the atomisation is coarse or if the flow rate is...

Page 18: ...w rate of paint and air for the best spray pattern to find out the right flow rate of paint and air for the best spray pattern Detailed information about these settings can be found in chapter 11 15 D...

Page 19: ...finish of the object to be coated it may be advisable to vary the amount of air Very low viscosity materials such as watery glazes do not have to be atomised with the maximum amount of air In this ca...

Page 20: ...he object Fig 12 C INCORRECT An uneven distance will result in uneven paint application Move the spray gun evenly cross wise or up and down depending on the spray pattern setting An even movement of t...

Page 21: ...4 Unscrew the container Empty any remaining coating material back into the material tin 5 Preclean the container and feed tube with a brush Clean the ventilating bore Fig 14 1 19 Cleaning the Wall Ext...

Page 22: ...ray gun with metal objects The ventilation hose and diaphragm are only solvent resistant to a limited extent Do not immerse in solvent only wipe 6 The unit may only be operated with an integer diaphra...

Page 23: ...e ventilating hose Fig 15 1 at the top from the gun body Screw off the valve cover 2 Remove the diaphragm 3 Carefully clean all parts or replace in the event of damage 2 Place the diaphragm Fig 15 3 w...

Page 24: ...king or R Container seal marking AR or AU 2323 039 2370 527 9 Container with cover 800 ml 0413 909 Beforeplacingtheorder pleasecheckthebottomoftheinside of your spray attachment to see if there is a m...

Page 25: ...rge or replace Clean Clean Increase the quantity of material Insert Tighten container Clean Coating material drips from the nozzle Nozzle loose Nozzle worn Nozzle seal is missing or worn Coating mater...

Page 26: ...al Data Technical Data Max viscosity Interior wall paint Wall Extra I Spray spray attachment 4000 mPas Rechargeable battery PBA 18 V 2 5 Ah Li Ion 18 V 2 5 Ah Atomizing output 200 W Max flow rate Inte...

Page 27: ...26 Environmental protection Attheendofitsservicelife theappliance includingaccessoriesandpackaging must be recycled in an environmentally friendly manner Separate packaging materials by type and put...

Page 28: ...the product is registered within 28 days of purchase on the Internet at https go wagner group com 3plus1 The guarantee includes the free repair of defects which are demonstrably caused by the use of u...

Page 29: ...uses approved by ASTA in accordance with BS 1362 5 Amp fuses may be used To ensure that the fuse and fuse carrier are correctly mounted please observe the provided markings or colour coding in the plu...

Page 30: ...T 45 70 234 239 E CORECO SK S R O Kr ovsk ulica 8 7133 927 01 a a T 42 1948882850 F 42 1313700077 PUT WAGNER SERVICE ul E Imieli 27 41 605 Swietochlowice T 48 32 346 37 00 F 48 32 346 37 13 D F DK S...