background image

INSTRUCTIONS FOR:

HVLP SPRAY GUN SYSTEM

MODEL :

HVLP2002

Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and

properly maintained, give you years of trouble free performance.

HVLP2002 - 2 - 160502

1. SAFETY INSTRUCTIONS

IMPORTANT:

PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS AND

CAUTIONS. USE THIS PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY

CAUSE DAMAGE OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.

1.2.

GENERAL SAFETY.

3

Familiarise yourself with the application, limitations and potential hazards peculiar to the spray gun.

p

WARNING!

Disconnect the spray gun from the air hose before changing accessories, servicing or performing any maintenance.

3

Maintain the spray gun in good condition (use an authorised service agent).

3

Replace or repair damaged parts. 

Use recommended parts only. Unauthorised parts may be dangerous and will invalidate the warranty.

3

Keep the spray gun clean for best and safest performance.

3

Wear approved safety respiratory protection and safety goggles.

3

Remove ill fitting clothing. Remove ties, watches, rings, and other loose jewellery, and tie back long hair.

3

Locate the spray gun in the desired working area, keep area clean and tidy and free from unrelated materials and ensure that there is

adequate ventilation and lighting.

3

Keep children and unauthorised persons away from the working area.

3

Avoid unintentional operation.

7

DO NOT point spray gun at yourself, other persons or animals.

7

DO NOT carry the spray gun by the hose, or yank the hose from the air outlet. 

7

DO NOT use the spray gun for any purpose other than for which it is designed.

7

DO NOT allow untrained persons to operate the spray gun.

7

DO NOT get the spray gun wet and DO NOT use outside or in damp or wet locations or areas where there is condensation.

7

DO NOT operate the spray gun if any parts are missing or damaged as this may cause failure and/or possible personal injury.

7

DO NOT direct air from the air hose at yourself or at others.

3

When not in use switch the unit off and disconnect from the mains. 

7

DO NOT use the machine in the presence of flammable liquids or gases.

7

DO NOT use the machine on premises where explosive substances are stored.

7

DO NOT open the main unit or loosen or remove any of its retaining screws.

7

DO NOT wipe plastic parts with any solvents such as petrol, thinners, carbon tetrachloride, alcohol or ammonia.

1.1.

ELECTRICAL SAFETY. 

p

p

 

 

WARNING! It is the user’s responsibility to read, understand and comply with the following:

You must check all electrical equipment and appliances to ensure they are safe before using. You must inspect power supply leads, plugs and

all electrical connections for wear and damage. You must ensure the risk of electric shock is minimised by the installation of appropriate safety

devices. An RCCB (Residual Current Circuit Breaker) should be incorporated in the main distribution board. We also recommend that an RCD

(Residual Current Device) is used with all electrical products. It is particularly important to use an RCD with portable products that are plugged

into an electrical supply not protected by an RCCB. If in doubt consult a qualified electrician. You may obtain a Residual Current Device by

contacting your Sealey dealer. 

You must

also read and understand the following instructions concerning electrical safety.

1.1.1. The 

Electricity At Work Act 1989

requires all portable electrical appliances, if used on business premises, to be tested by 

a qualified electrician, using a Portable Appliance Tester (PAT), at least once a year.

1.1.2. The 

Health & Safety at Work Act 1974

makes owners of electrical appliances responsible for the safe condition of the appliance

and the safety of the appliance operator. 

If in any doubt about electrical safety, contact a qualified electrician.

1.1.3. Ensure the insulation on all cables and the product itself is safe before connecting to the mains power 

supply. See 1.1.1. & 1.1.2. above and use a Portable Appliance Tester (PAT).

1.1.4. Ensure that cables are always protected against short circuit and overload.

1.1.5. Regularly inspect power supply, leads, plugs for wear and damage and all electrical connections 

to ensure that none is loose. 

1.1.6.

Important:

Ensure the voltage marked on the product is the same as the electrical power supply

to be used and check that plugs are fitted with the correct capacity fuse. A 13 amp plug may require 

a fuse smaller than 13 amps for certain products

,

see fuse rating at right. 

1.1.7. DO NOT pull or carry the powered appliance by its power supply lead.

1.1.8. DO NOT pull power plugs from sockets by the power cable.

1.1.9. DO NOT use worn or damaged leads, plugs or connections. Immediately replace or have repaired by 

a qualified electrician. A U.K. 3 pin plug with ASTA/BS approval is fitted. In case of damage, cut off 

and fit a new plug according to the following instructions (discard old plug safely).

(UK only - see diagram at right). 

Ensure the unit is correctly earthed via a three-pin plug. 

a)  Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.

b) Connect the BROWN live wire to live terminal ‘L’.

c)  Connect the BLUE neutral wire to the neutral terminal ‘N’.

After wiring, check there are no bare wires, that all wires have been correctly connected, that cable outer insulation

extends beyond the cable restraint and that the restraint is tight.

Double insulated products are often fitted with live (BROWN) and neutral (BLUE) wires only. Double insulated products are always marked with

this symbol       .

To re-wire, connect the brown & blue wires as indicated above. DO NOT 

connect the brown or blue to the earth terminal.

1.1.10. Some products require more than a 13 amp electrical supply. In such a case, 

NO

plug will be fitted. 

You must

contact a qualified electrician 

to ensure a 30 amp fused supply is available. We recommend you discuss the installation of a industrial round pin plug and socket with your electrician. 

1.1.11.

Cable extension reels

. When a cable extension reel is used it should be fully unwound before connection. A cable reel with an RCD

fitted is recommended since any product which is plugged into the cable reel will be protected. The section of the cores of the cable

is important. We suggest 1.5mm

2

section as a minimum but to be absolutely sure that the capacity of the cable reel is 

suitable for this product and for others that may be used in the other output sockets, we recommend the use of 2.5mm

2

section cable.

Blue

Neutral 

Wire

Yellow & Green 

Earth Wire 

Cable 

Restraint

FUSE RATING

THIS PRODUCT MUST BE FITTED 

WITH A 

13 AMP FUSE

Brown

Live 

Wire

Summary of Contents for HVLP2002

Page 1: ...n electrical supply not protected by an RCCB If in doubt consult a qualified electrician You may obtain a Residual Current Device by contacting your Sealey dealer You must also read and understand the following instructions concerning electrical safety 1 1 1 The Electricity At Work Act 1989 requires all portable electrical appliances if used on business premises to be tested by a qualified electri...

Page 2: ...t when using paint that has previously been opened The paint should be thoroughly mixed and free from skin and lumps If necessary strain the paint through a 60 mesh paint strainer or a piece of cheesecloth or an old nylon stocking to ensure a smooth finish The paint should be strained into a clean container and if any paint is left over it should be stored in a clean container 7 DO NOT mix or thin...

Page 3: ...arts hand tight to avoid cross threading If a part cannot easily be turned by hand check that you have the correct part unscrew realign and try again DO NOT use excessive force when reassembling 7 2 Cleaning the spray gun To maintain the spray gun in peak operational condition the main parts as shown in fig 7 should be regularly inspected and cleaned Metal parts should be soaked in a suitable pain...

Page 4: ...ide pattern Top heavy or bottom heavy pattern Intermittent spray pattern HVLP2002 2 160502 01284 757500 E mail sales sealey co uk 01284 703534 Sole UK Distributor Sealey Group Bury St Edmunds Suffolk NOTE It is our policy to continually improve products and as such we reserve the right to alter data specifications and component parts without prior notice IMPORTANT No responsibility is accepted for...

Reviews: