OPERATING MANUAL
EDITION 04/2010
PART NO. DOC393831
6.6
FILLING THE UNIT AND CALIBRATION
6.6.1
FILLING THE UNIT
SIHI_0061_GB
WARNING
Do not exchange the two components A and B!
Equipment damage by hardened paint
Mark unit parts and paint container, so that the components A
and B are not exchanged.
➞
Using the same procedure as for fi lling the system with cleaning agent, the main
material is now conveyed into the A-circuit and the hardening material into the B-
circuit in circulation mode.
6.6.2
CALIBRATION THE UNIT
➞
The system is volumetrically calibrated in the factory, therefore it does not have to be
calibrated with the material. However, if a calibration is required, proceed as follows:
1. The material to be calibrated is fi rst of all conveyed manually as far as the gun.
2. Set the pump pressure to 0.5 MPa; 5 bar; 73 psi and select the nozzle so that the material
fl ow volume corresponds to the subsequent production process.
3. Start the calibration process for the A side with the [Start] key.
4. A minimum of 5 pump double strokes are discharged into a measuring cup with the
gun (use protective sleeve against over spray if necessary).
The
fl ow volume measured by the control is shown on the display.
5. Press button [STOP]
6. The quantity discharged into the measuring cup in cm
3
is entered by pressing [SET]
and „+“ „-“ and confi rmed by pressing [SET].
Attention:
The calibration process can be interrupted without saving by pressing the
Stop button.
7. The control has now calculated and saved the new K-factor and displays it.