22
PEM-X1
P_01664
P_01664
P_01665
P_02209
OPERATING MANUAL
VERSION 03/2014
ORDER NUMBER DOC 2326020
6.4
PREPARING THE SPRAY GUN
6.4.1
SELECTION OF THE SUITABLE NOZZLE SYSTEM
Nozzle
Application
Distance to
work piece
Powder output
(mm)
(g/min)
Universal
120 ... 300
50 ... 300
Deep and complex part
geometries
Extensive work pieces
The spray width can be adjusted by the sliding ring.
Rear sliding ring
Wide cloud
Cloud opening angle approx. 80°
Front sliding ring, front
Narrow cloud
Cloud opening angle approx. 60°
Front sliding ring, front, turned by 90°
Extra narrow cloud
Cloud opening angle approx. 40°
Nozzle
Application overview
Powder cloud
Fan spray nozzle
Complex part geometries
Widely spread fl at powder cloud
Flat work pieces
(reduced picture frame)
Profi les
Undercuts
Defl ector cone
Round powder cloud:
Wire goods
Size of the powder cloud is
dependent on the defl ector plate
diameter
Grid designs
Small components
The process of changing from the fan spray nozzle to the defl ector cone is described in
Chapter 8.8 "Changing from Fan spray nozzle to Round spray nozzle".
You will fi nd the article numbers of the diff erent nozzles in Chapter 12 "Accessories".