18
PEM-X1
OPERATING MANUAL
VERSION 03/2014
ORDER NUMBER DOC 2326020
Dimensions:
Length/width/height
see Chapter 5.3.1
Weight
490 g; 1.08 lbs
Electrical:
Input voltage
maximum 22 Vpp
Input current
maximum 0.9 A
Frequency
19 - 30 kHz
Output voltage
maximum 100 kV DC
Maximum Corona current
120 μA
Polarity
negative
Construction type
in accordance with EN 50050-2
Protection class
Pneumatic:
Input air pressure (atomizing air volume)
maximum 3 bar; 0.3 MPa, 43.51 psi
Powder output quantity
maximum 450 g/min;
maximum 0.99 lbs/min
Ambient conditions:
Operating temperature range
5 - 45 °C; 41 - 113 °F
Relative humidity
5.3
TECHNICAL DATA
Ambient conditions:
If low-melting powders are used, the ambient temperature may have to be lower than
30 °C; 86 °F.
Volume measures:
for volumes specifi ed in Nm³ (standard cubic meters). One cubic meter of a gas at 0 °C and
1.013 bar is called norm cubic meter.
Outgoing air containing oil!
Risk of poisoning if inhaled.
Insuffi
cient paint application quality.
Provide compressed air free from oil and water
(Quality Standard 3.5.2 according to ISO 8573.1)
3.5.2 = 5 μm / +7 °C; 44.6 °F / 0.1 mg/m³.
WARNING