4.2.1
SAFE HANDLING OF WAGNER POWDER SPRAY DEVICES
4.2.2
GROUNDING THE DEVICE
4.2.3
PRODUCT HOSES
4.2
SAFETY INSTRUCTIONS FOR STAFF
Only use an original Wagner powder hose.
Always follow the information in this manual, particularly the general safety instructions
and the warning instructions.
Always follow local regulations concerning occupational safety and accident
prevention.
Under no circumstances may people with pacemakers enter the area where the
high-voltage fi eld between the spray gun and the work piece to be coated builds up!
Do not point spray guns at people.
Before all work on the device, in the event of work interruptions and functional faults:
- Switch off the energy/compressed air supply.
- Secure the spray gun against actuation.
- Relieve pressure on spray gun and device.
- In case of functional faults: Identify and correct the problem, proceed as described in
the "Fault Rectifi cation" chapter.
The electrostatic charge may, in certain cases, give rise to electrostatic charges on the
device. This may result in the formation of sparks or fl ames when discharging.
Ensure that the device is grounded before each coating process.
All the system's conductive elements, such as fl oors, walls, ceilings, protective
grating, transport equipment, work pieces, powder tanks, automatic moving devices
or construction parts etc. in the spray area, with the exception of parts which carry
high-voltage during operation, must be connected to the grounding system.
Parts of the booth must be grounded in accordance with EN 12981.
Ensure that all persons inside the working area are grounded, e.g., by wearing
electrostatically conductive shoes.
The functionality of grounding cables must be checked regularly (see EN 60204).